Manual

23
2002 Top Dry Service School
Programming Set-up Variables
Turn the Control Power “ off “
Turn the Control Power switch “ on “
with the Program Temperature switch
held down.
Press the Increase switch until 3 is on
the display.
Press the Program Temperature switch
again.
•C or no C will bill displayed.
Use the Increase or Decrease switch to
toggle between C or no C.
C - Hi-Lo cycling heater
no C - On/Off cycling heater
When the correct selection is on the
screen press the Program Tempera-
ture switch again.
•H or no H will be displayed.
Use the Increase or Decrease switch to
toggle between H or no H.
H - Humidity sensor present
no H - No humidity sensor
present
When the correct selection is on the
screen press the Program Temperature
switch again.
•F or C will be displayed.
Use the Increase or Decrease switch to
toggle between F or C.
F - Temperatures displayed in
Fahren- heit.
C-Temperatures displayed in
Celsius.
When the correct selection is on the
screen press the Program Temperature
switch again.
•L or no L will be displayed.
Use the Increase or Decrease switch
to toggle between L or no L.
L - The dryer will advance to
the Cool cycle when the Dry
timer has reached zero and the
Grain temperature set point
has been met.
noL - The dryer will advance
to the Cool cycle when either
the Dry timer has reached zero
or the Grain temperature set
point has been met.
When the correct selection is on the
screen press the Program Temperature
switch again.
Series 2000 Batch Fan / Heater