MD4300 Blood pressure monitor Instructions for use
ENGLISH Contents 1. Getting to know your device ............................................... 2. Important notes ................................................................... 3. Device description .............................................................. 4. Preparing the measurement ................................................ 5. Measuring blood pressure .................................................. 6. Evaluating results ................................................................
Application part, type BF Direct current Disposal in accordance with the Waste Elec trical and Electronic Equipment EC Directive – WEEE Manufacturer Stor age Permissible storage temperature and hu midity 70°C -25°C - RH ≤93% Oper ating 40°C 5°C Permissible operating temperature and humidity RH 15-93 % Protect from moisture Serial number SN 0123 The CE labelling certifies that the product complies with the essential requirements of Directive 93/42/EEC on medical products.
• Please note that when inflating, the functions of the limb in question may be impaired. • During the blood pressure measurement, the blood circulation must not be stopped for an unnecessarily long time. If the device malfunctions remove the cuff from the arm. • Do not allow sustained pressure in the cuff or frequent measurements. The resulting restriction of the blood flow may cause injury.
• Do not use rechargeable batteries. • Do not disassemble, open or crush the batteries. 3. Device description Instructions for repairs and disposal • Batteries do not belong in household waste. Please dispose of empty batteries at the collection points intended for this purpose. • Do not repair or adjust the device yourself. Proper operation can no longer be guaranteed in this case. • Repairs must only be carried out by Customer Services or authorised suppliers. • Do not open the device.
Information on the display: 1 1. Time/date 2. Systolic pressure 12 3. Diastolic pressure 4. Calculated pulse value 5. Irregular heartbeat 11 symbol 10 6. Pulse symbol 7. User memory 8. Classification of 9 measurements 9. Number of memory space/memory display for average 8 7 value ( ), morning ( ), evening ( ) 10. Release air (arrow) 11. Battery display symbol 12. Symbol for Bluetooth® transfer 4. Preparing the measurement 2 3 4 6 5 System requirements for the HealthCoach app Bluetooth®4.
➔ Date ➔ Time ➔ Bluetooth ® Date Hour format The day flashes on the display. • Select the current day using the M1/M2 memory buttons and confirm with the START/STOP button . If you have set the 12h hour format, the month is displayed before the day. Time Set the hour format, date, time and Bluetooth® settings The following section describes the functions and settings available on the blood pressure monitor. The hours flash on the display.
5. Measuring blood pressure Attach the cuff 1 2 3 m 1c Otherwise significant deviations can occur. Relax your arm and the palm of your hand. • To avoid falsifying the measurement, it is important to remain still during the measurement and not to speak! Performing the blood pressure measurement As described above, attach the cuff and adopt the posture in which you want to perform the measurement. Adopt the correct posture • Before every measurement, relax for about five minutes.
Measurement • Press the START/STOP button to switch off the blood pressure monitor. The measurement is then stored in the selected user memory. • If the device is not switched off manually, it will switch off automatically after 3 minutes. If Bluetooth ® data transfer has been activated, data is by transferred after having confirmed the user memory by pressing the pressing the START/STOP button . • The Bluetooth ® symbol flashes on the display.
Classification of measurements: The measurements can be classified and evaluated in accordance with the following table. However, these standard values serve only as a general guideline, as the individual blood pressure varies in different people and different age groups etc. It is important to consult your doctor regularly for advice. Your doctor will tell you your individual values for normal blood pressure as well as the value above which your blood pressure is classified as dangerous.
Average values Press the M1 button if you have selected user memory 1. Press the M2 memory button if you have flashes on the display. The average value of all saved measured values in this user memory is displayed. • Press the relevant memory button ( M1 or M2 ). Average values Individual measured values User memory • To view the measurement data for user memory , press the M2 memory button. The average of all measurements appears on the display.
Deleting individual measurements Delete the measured values • To clear the memory of the relevant user memory, you must first select a user memory. • Start the retrieval of the average measured values. A flashes on the display and the average value of all saved measured values in this user memory is displayed. • Press and hold the memory button M1 or M2 for 5 seconds depending on the user memory you are in. All the values in the current user memory are deleted.
Step 4: MD4300 data transfer immediately following measurements. • If Bluetooth ® data trans fer has been activated, data is by transferred after having confirmed the user memory by pressing the pressing the START/STOP button . Step 4: MD4300 Data transfer at a later point: • Go to memory mode (chapter 7). Select the desired user memory. The Bluetooth ® transfer starts automatically. The HealthCoach app must be active to allow data transfer.
Measurement inac curacy Memory Dimensions Weight Cuff size Permissible operating conditions Permissible storage conditions Power supply Battery life Accessories Classification Max. permissible standard deviation according to clinical testing: Systolic 8 mmHg / Diastolic 8 mmHg 2 x 60 memory spaces L 78 mm x W 63 mm x H 23 mm 66.5 g (Without cuff and batteries) 14 to 19.
for the basic safety and essential performance of automated non-invasive sphygmomanometers). • The accuracy of this blood pressure monitor has been carefully checked and developed with regard to a long useful life. If using the device for commercial medical purposes, it must be regularly tested for accuracy by appropriate means. Precise instructions for checking accuracy may be requested from the service address. • We hereby guarantee that this product complies with the European R&TTE Directive 1999/5/EC.
11. FCC statement Changes or modifications to the product not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pur-suant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Symbol for the marking of electrical and electronics devices according to Directive 2002/96/EC. The device, accessories and the packaging have to be disposed of waste correctly at the end of the usage. Please follow Local Ordinances or Regulations for disposal. Grandway Technology (Shenzhen) Limited, No.5 the Second Industrial Zone, Zhukeng Community, Longtian Street, Pingshan District, Shenzhen, 518118, The PEOPLE’S REPUBLIC OF CHINA Shanghai International Trading Corp.