SDS

Product name: GREAT STUFF Big Gap Filler Insulating Foam
Sealant 12oz HC ES SASTW 12ct
Issue Date: 06/07/2018
Page 7 of 19
from the source of vapor/aerosol generation and people working at this point. The odor and irritancy
of this material are inadequate to warn of excessive exposure. Lethal concentrations may exist in
areas with poor ventilation.
Individual protection measures
Eye/face protection: Use safety glasses (with side shields).
Skin protection
Hand protection: Use gloves chemically resistant to this material. Examples of
preferred glove barrier materials include: Butyl rubber. Chlorinated polyethylene.
Polyethylene. Ethyl vinyl alcohol laminate ("EVAL"). Examples of acceptable glove
barrier materials include: Neoprene. Nitrile/butadiene rubber ("nitrile" or "NBR").
Viton. Polyvinyl chloride ("PVC" or "vinyl"). NOTICE: The selection of a specific glove
for a particular application and duration of use in a workplace should also take into
account all relevant workplace factors such as, but not limited to: Other chemicals
which may be handled, physical requirements (cut/puncture protection, dexterity,
thermal protection), potential body reactions to glove materials, as well as the
instructions/specifications provided by the glove supplier.
Other protection: Use protective clothing chemically resistant to this material.
Selection of specific items such as face shield, boots, apron, or full body suit will
depend on the task.
Respiratory protection: Atmospheric levels should be maintained below the exposure
guideline. When atmospheric levels may exceed the exposure guideline, use an approved air-
purifying respirator equipped with an organic vapor sorbent and a particle filter. For situations
where the atmospheric levels may exceed the level for which an air-purifying respirator is
effective, use a positive-pressure air-supplying respirator (air line or self-contained breathing
apparatus). For emergency response or for situations where the atmospheric level is
unknown, use an approved positive-pressure self-contained breathing apparatus or positive-
pressure air line with auxiliary self-contained air supply. In confined or poorly ventilated areas,
use an approved self-contained breathing apparatus or positive pressure air line with auxiliary
self-contained air supply.
The following should be effective types of air-purifying respirators: Organic vapor cartridge
with a particulate pre-filter.
9. PHYSICAL AND CHEMICAL PROPERTIES
Appearance
Physical state
Foam
Color
Yellow
Odor
Mild
Odor Threshold
No test data available
pH
Not applicable
Melting point/range
No test data available
Freezing point
No test data available
Boiling point (760 mmHg)
Not applicable
Flash point
closed cup -104 °C ( -155 °F) Estimated.
Evaporation Rate (Butyl Acetate
= 1)
No test data available
Flammability (solid, gas)
Not expected to form explosive dust-air mixtures.