User Manual

13
8. Wiring Power, Ground, Airflow Meter,Throttle, RPM Signal
for RB26DETT (with 2 airflow meters)
× ×
Yellow (Airflow Input 2)
White (Airflow Input 1)
Female connector
Male connector
Splice
Gray (Throttle signal)
* The 2 wires for the airflow meter on the ECU will be connected together to the Airflow Output
wire.
* Make sure the jumper JP10 is set to “1-2” in the unit. This activates the Airflow Input 2 wire.
* Always use the provided connectors or solder all connections.
Important
ECU
(Engine Control Unit)
Red (12v IG power)
Black (ECU Ground)
Brown (rpm signal)
Green (Airflow Output)
If the Ignition signal, Crank angle signal, or Cam angle signal wire is going to be wired, the
unit does not require the rpm signal wire to be connected to pick up rpm signal.
Connector B