Specification Sheet

2
Technical Data
November 2014
VSW-P – PIR/Single Level 120V Vacancy Sensor (Ground Required)
www.coopercontrol.com
Specifications
Technology
Passive Infrared (PIR)
Electrical
Ratings
(Per Relay)
120 VAC:
Incandescent/Tungsten –
Max. load: 5A, 600W, 60 Hz
LED/Compact Fluorescent/Ballast –
Max. load: 5A, 600W, 60 Hz
Motor Load: 1/6 HP @ 125 VAC
Coverage
Major motion - 450 sq. ft.
Minor motion - 200 sq. ft.
Light Level
Sensing
0 to 200 foot-candles
Operating
Environment
Temperature: 32°F - 104°F (0°C - 40°C)
Relative humidity: 20% to 90% non-condensing
For indoor use only
Housing
Durable, injection molded housing. Resin
complies with UL 94V-0
Size
Mounting Plate/Strap Dimensions:
4.2”H x 1.8”W (106.5mm x 46mm)
Product Housing Dimensions:
2.87”H x 1.6”W x 1.42”D (72.8mm x 40.7mm x
36mm)
Standards
FCC Compliant
cULus Listed
RoHS Compliant
Description/Operation
VSW-P-0801-120 uses Passive Infrared (PIR) sensor technology to
monitor a room for occupancy and deliver maximum energy savings.
The lights are turned ON by pressing the pushbutton. The sensor
provides true multi-way ON/OFF control. When lights have been
activated, the lights will remain ON as long as on the sensor(s)
continue to detect motion. The occupant may manually turn OFF
the lighting by pressing the ON/OFF button on any of the connected
devices. If the room becomes vacant and the lights are ON, the
lights will turn OFF when the unit that detected motion last times-
out. PIR sensors are considered line-of-sight sensors, meaning that
the sensor must be able to have a direct line-of-sight to the person
making the motion.
Applications
Home Office
Residential Room
Small Office
Residential Restroom
Residential Hallway