Diaphragm:
The diaphragm makes the electric connection between re-
ference system and sample� Additionally it should prevent
the spoiling of the reference electrolyte by the
measured medium�
Ceramic diaphragm
Porous ceramic rods ensure low leak rates�
Application:
General applications in clean till lightly
soiled media�
Joint / movable joint
The roughened surface between the cut glass
of the electrode and a cut glass sleeve permits
a electrolyte ow of several ml / h�
Application:
low-ion or heavily soiled samples
Pellon diaphragm
A permeable diaphragm made of Pellon texture
is used for fast response times and stable
measuring values
Application:
Clean till lightly soiled media�
PH ELECTRODES
GE 100 GE 101 GE 104 GE 108 GE 114 GE 117 GE 120 GE 125 GE 126 GE 151 GE 171 GE 173
Measuring
range
0 ��� 14 pH
0 ��� 80 °C
2 ��� 11 pH
0 ��� 60 °C
0 ��� 14 pH
0 ��� 80 °C
0 ��� 14 pH
0 ��� 80 °C
0 ��� 14 pH
0 ��� 60 °C
0 ��� 14 pH
0 ��� 80 °C
0 ��� 14 pH
0 ��� 60 °C
0 ��� 14 pH
0 ��� 70 °C
0 ��� 14 pH
-5 ��� +80 °C
0 ��� 14 pH
0 ��� 80 °C
0 ��� 14 pH
0 ��� 140 °C
0 ��� 14 pH
0 ��� 80 °C
Conductivity >100 µS / cm >100 µS / cm >20 µS / cm >100 µS / cm >200 µS / cm >100 µS / cm >200 µS / cm >200 µS / cm >100 µS / cm >100 µS / cm >100 µS / cm >50 µS / cm
Temperature
measuring
no no no no no
integr
Pt1000
4 mm
banana
no
integr
Pt1000
4 mm
banana
no no no no
Water-proof no no no no optional no no ja no no no no
Pressure
resistant
no no no 6 bar no 6 bar no 1 bar 5�5 bar no 10 bar 6 bar
Cable 1 m
1)
1 m
1)
1 m
1)
2 m
1)
1 m 2 m
2)
1 m 2 m 5 m 1 m
1)
ohne 1 m
1)
Electrolyte 3 mol/l KCl 3 mol/l KCl 3 mol/l KCl
gel
electrolyte
gel
electrolyte
gel
electrolyte
gel
electrolyte
gel
electrolyte
gel
electrolyte
3 mol/l KCl
gel
electrolyte
gel
electrolyte
Diaphragm 2 x ceramic 2 x ceramic moving joint 2 x ceramic 1 x Pellon 2 x ceramic 2 x ceramic 1 x ceramic 2 x ceramic 1 x ceramic 2 x ceramic joint
Thread without without without PG 13�5 without PG 13�5 without without 1/2" NPT without PG 13�5 PG 13�5
Electrode
shaft
tyril,
Ø 12 mm x
120 mm
glass, Ø 12
or 6 mm x
120 mm
glass,
Ø 12 mm x
120 mm
PSU,
Ø 12 mm x
120 mm
epoxide,
Ø 12 mm x
120 mm
PSU,
Ø 12 mm x
120 mm
PVC,
Ø 22 mm x
110 mm
epoxide,
Ø 12 mm x
120 mm
ABS
Ø 26�4 mm x
147 mm
glass,
Ø 12 mm x
120 mm
glass,
Ø 12 mm x
120 mm
glass,
Ø 12 mm x
120 mm
Features
universal
electrode
tip Ø 6 mm,
small sample
volume
for low-ion
media
low-
maintenance
Low-cost
low-
maintenance
temperature
compen-
sated
insertion
electrode,
blade Ø 13
mm x 60 mm
submersible,
water-proof
IP67 (also
BNC-plug)
extremely
low-
maintenance
chemicals-
resistant
glass shaft
for extreme
conditions,
sterilizable,
autoclavable
for process
chemistry,
bio-che-
mistry, alkali-
resistant
Connection:
BNC
Art. no.
600704
600693
602063
600713
604701
600730
600698 600731
610987
600727
-
600735
S7*)
Art. no.
- - -
606089
- - - - -
606375
606572
*) Note: cable GEAK-2S7-BNC or GEAK-5S7-BNC is needed for connection S7, for devices with cinch connection adapter GAD 1 BNC is necessary.
Electrodes are consumption objects. Lifetime under careful treatment: >2 years; warranty: 12 months
Reference electrolyte:
The reference electrolyte oers a constant voltage of the
reference system and makes the electrical connection
between sample and reference electrode�
Liquid electrolyte
Mainly 3 mol / l KCl is used� Liquid electrolytes oer fast
response times in general and can be replaced if contami-
nated�
Gel electrolyte
The electrolyte is solidied for low-maintenance electrodes
able to measure irrespective to its position� Under normal
measurement conditions no noticeable electrolyte leakage
is observable�
Electrodes with S7 connection:
The electrodes are oered with an S7 industrial screw plug
tted, also known as industrial-S8 Plug head� In contrast to
S7 lab plug head this one is for direct installation in ttings
with PG 13�5 suitable thread�
Options:
Longer cable for
1) 2)
(available cable lengths: up to 5 m)
Special designs
(electrodes with thread, other lengths, special applications
etc�)
Accessories and spare parts:
Kabel-BNCM/BNCF
Art. no. 606158
Extension cables for electrodes with BNC connector,
Cable length: 3 m
glass sleeve
Pellon strap
ceramic rod
STERILIZABLE
BNC connection
S7 connection at shaft
NEW!