G0457 14" Industrial Bandsaw (Mfd. Since 5/11)
Improper connection of the equipment-grounding
wire can result in a risk of electric shock. The
wire with green insulation (with or without yellow
stripes) is the equipment-grounding wire. If repair
or replacement of the power cord or plug is nec-
essary, do not connect the equipment-grounding
wire to a live (current carrying) terminal.
Check with a qualified electrician or service per-
sonnel if you do not understand these grounding
requirements, or if you are in doubt about whether
the tool is properly grounded. If you ever notice
that a cord or plug is damaged or worn, discon-
nect it from power, and immediately replace it with
a new one.
Grounding Requirements
This machine MUST be grounded. In the event
of certain malfunctions or breakdowns, grounding
reduces the risk of electric shock by providing a
path of least resistance for electric current.
Figure 2. Typical 5-20 plug and receptacle.
Grounding Prong
Hot
Neutral
5-20 PLUG
GROUNDED
5-20 RECEPTACLE
Figure 1. Typical 6-15 plug and receptacle.
Grounding Prong
Current Carrying Prongs
6-15 PLUG
GROUNDED
6-15 RECEPTACLE
Serious injury could occur if you connect
machine to power before completing setup
process. DO NOT connect to power until
instructed later in this manual.
For 220V operation: This machine is equipped
with a power cord that has an equipment-ground-
ing wire and a grounding plug (see following fig-
ure). The plug must only be inserted into a match-
ing receptacle (outlet) that is properly installed
and grounded in accordance with all local codes
and ordinances.
For 110V operation: The plug specified in the
circuit requirements has a grounding prong that
must be attached to the equipment-grounding
wire inside the included power cord. The plug
must only be inserted into a matching receptacle
(see following figure) that is properly installed and
grounded in accordance with all local codes and
ordinances.