Product Manual
Table Of Contents
- 1. SQ, SQE introduction
- 2. SQ, SQE applications
- SQ with pressure switch and pressure tank
- Constant-pressure control with CU 301, residential water supply
- Constant-pressure control with CU 301, irrigation
- Maintaining a constant water table
- Emptying or filling a tank
- Pumping from one tank to another
- Setting of operating parameters
- SQE with manual speed control
- 3. Performance range
- 4. SQ, SQE installation
- 5. Sizing and selection
- 6. Cable sizing
- 7. SQ, SQE curve charts
- 8. SQ, SQE technical data
- 9. SQ, SQE construction
- 10. CU331SP variable frequency drive
- 11. Accessories
- 12. SP introduction
- 13. SP product overview
- 14. SP construction
- 15. SP operating conditions
- 16. How to read the curve charts
- 17. SP curve charts and technical data
- 4" and larger wells
- SP 5S (5 gpm)
- SP 7S (7 gpm)
- SP 10S (10 gpm)
- SP 16S (16 gpm)
- SP 25S (25 gpm)
- SP 35S (35 gpm)
- SP 45S (45 gpm)
- SP 62S (62 gpm)
- SP 77S (77 gpm)
- 6" and larger wells
- SP 85S (85 gpm)
- SP 150S (150 gpm)
- SP 230S (230 gpm)
- SP 300S (300 gpm)
- 8" and larger wells
- SP 385S (385 gpm)
- SP 475S (475 gpm)
- 10" and larger wells
- SP 625S (625 gpm)
- SP 800S (800 gpm)
- SP 1100S (1100 gpm)
- 18. SP electrical data
- 19. Accessories
- 20. Energy consumption
- 21. Cables
- 22. Friction loss tables
- 23. Grundfos Product Center
SP curve charts and technical data
SQ, SQE, CU 331, and SP
17
127
10" and larger wells - continued
SP 800S (800 gpm) / 6, 8 inch motors
Notes:
Control box is required for 3-wire, single-phase applications. Data does not include control box.
Performance conforms to ISO 9906. 1999 (E) Annex A. Minimum submergence is 2 feet.
Pump model
Nom.
head
[ft]
Ph
Volts
[V]
Motor
[Hp]
Dimensions
Net weight
(complete)
[lb]
800S
ABCDE
TM00 8760 3596
[in. (mm)] [in. (mm)] [in. (mm)] [in. (mm)] [in. (mm)]
800S - Motor dia. 6 inch, 60 Hz, rated flow 800 gpm (6" NPT)
800S200-1A 64
3 230 20 ▲ 56.50 (1435) 30.83 (783) 25.67 (652) 5.63 (143) 8.31 (211) 180.0
3 460 20 ▲ 56.50 (1435) 30.83 (783) 25.67 (652) 5.63 (143) 8.31 (211) 180.0
800S300-1 96
3 230 30 ▲ 61.23 (1555) 35.56 (903) 25.67 (652) 5.63 (143) 8.31 (211) 202.5
3 460 30 ▲ 61.23 (1555) 35.56 (903) 25.67 (652) 5.63 (143) 8.31 (211) 202.5
800S400-2AA 131 3 460 40 ▲ 72.05 (1830) 40.28 (1023) 31.78 (807) 5.63 (143) 8.31 (211) 257.4
800S500-2A 162 3 460 50 ☼ 88.00 (2235) 56.11 (1425) 31.87 (810) 7.56 (192) 8.39 (213) 363.2
800S500-2 194 3 460 50 ☼ 88.00 (2235) 56.11 (1425) 31.87 (810) 7.56 (192) 8.39 (213) 363.2
800S600-3AA 197 3 460 60 * 87.92 (2233) 50.00 (1270) 37.92 (963) 7.56 (192) 8.39 (213) 490.8
800S - Motor dia. 8 inch, 60 Hz, rated flow 800 gpm (6" NPT)
800S400-2AA 131 3 460 40 * 75.48 (1917) 43.71 (1110) 31.78 (807) 7.56 (192) 8.39 (213) 409.4
800S500-2A 162 3 460 50 * 77.45 (1967) 45.67 (1160) 31.78 (807) 7.56 (192) 8.39 (213) 431.4
800S500-2 187 3 460 50 * 77.45 (1967) 45.67 (1160) 31.78 (807) 7.56 (192) 8.39 (213) 438.0
800S600-3AA 229 3 460 60 * 87.92 (2233) 50.00 (1270) 37.92 (963) 7.56 (192) 8.39 (213) 490.8
800S750-3A 260 3 460 75 * 91.07 (2313) 53.15 (1350) 37.92 (963) 7.56 (192) 8.39 (213) 523.8
800S750-3 292 3 460 75 * 91.07 (2313) 53.15 (1350) 37.92 (963) 7.56 (192) 8.39 (213) 523.8
800S1000-4AA 327 3 460 100 * 106.62 (2708) 62.60 (1590) 44.02 (1118) 7.56 (192) 8.39 (213) 633.8
E = Maximum diameter
of pump including
cable guard and motor.
800S1000-4A 358 3 460 100 * 106.62 (2708) 62.60 (1590) 44.02 (1118) 7.56 (192) 8.39 (213) 633.8
800S1000-4 389 3 460 100 * 106.62 (2708) 62.60 (1590) 44.02 (1118) 7.56 (192) 8.39 (213) 633.8
800S1250-5AA 426 3 460 125 * 122.21 (3104) 72.05 (1830) 50.16 (1274) 7.56 (192) 8.39 (213) 748.3
800S1250-5A 456 3 460 125 * 122.21 (3104) 72.05 (1830) 50.16 (1274) 7.56 (192) 8.39 (213) 748.3
800S1250-5 487 3 460 125 * 122.21 (3104) 72.05 (1830) 50.16 (1274) 7.56 (192) 8.39 (213) 746.6
▲ MS 6000C motor.
☼ Takes MMS 6 motor; not available as complete.
* Takes MMS 8000 motor; not available as complete.
A
B C
E
D
Rp 6
NPT