SQ, SQE applications
SQ, SQE, CU 331, and SP
2
13
Setting of operating parameters
Using the R100 and the CU 300 enables change of the
motor speed and thereby setting of the pump to a
specific performance.
The software program "SQE Speed Calculation" has
been developed for the calculation of the speed in
order to obtain the required flow rate and head.
Dry-running protection
The value P
cut-out,
ensuring dry-running protection, is
factory-set for the SQE pump.
If the speed of the SQE pump is reduced by more than
1000 rpm, the P
cut-out
value must be readjusted by
means of the CU 300 and R100.
Fig. 11 Application example: Workshop setting of operating parameters
TM01 8650 4801
Note: The SQE pump must not be started until the
pump has been completely submerged below the water
table. However, the change of the motor speed can be
made even if the pump is not submerged.
R100
CU 300
SQE
Part Type No. of units Product number Unit price Total price
Pump SQE
Remote control R100
Control unit CU 300
SQE Speed Calculation program