Product Manual
Table Of Contents
- 1. SQ, SQE introduction
- 2. SQ, SQE applications
- SQ with pressure switch and pressure tank
- Constant-pressure control with CU 301, residential water supply
- Constant-pressure control with CU 301, irrigation
- Maintaining a constant water table
- Emptying or filling a tank
- Pumping from one tank to another
- Setting of operating parameters
- SQE with manual speed control
- 3. Performance range
- 4. SQ, SQE installation
- 5. Sizing and selection
- 6. Cable sizing
- 7. SQ, SQE curve charts
- 8. SQ, SQE technical data
- 9. SQ, SQE construction
- 10. CU331SP variable frequency drive
- 11. Accessories
- 12. SP introduction
- 13. SP product overview
- 14. SP construction
- 15. SP operating conditions
- 16. How to read the curve charts
- 17. SP curve charts and technical data
- 4" and larger wells
- SP 5S (5 gpm)
- SP 7S (7 gpm)
- SP 10S (10 gpm)
- SP 16S (16 gpm)
- SP 25S (25 gpm)
- SP 35S (35 gpm)
- SP 45S (45 gpm)
- SP 62S (62 gpm)
- SP 77S (77 gpm)
- 6" and larger wells
- SP 85S (85 gpm)
- SP 150S (150 gpm)
- SP 230S (230 gpm)
- SP 300S (300 gpm)
- 8" and larger wells
- SP 385S (385 gpm)
- SP 475S (475 gpm)
- 10" and larger wells
- SP 625S (625 gpm)
- SP 800S (800 gpm)
- SP 1100S (1100 gpm)
- 18. SP electrical data
- 19. Accessories
- 20. Energy consumption
- 21. Cables
- 22. Friction loss tables
- 23. Grundfos Product Center
Accessories
SQ, SQE, CU 331, and SP
19
134
Technical data - MP 204
Enclosure class IP20
Ambient temperature -4 °F to +140 °F (-20 °C to +60 °C)
Relative air humidity 99 %
Voltage range 100-480 VAC
Current range 3-999 A
Frequency 50 to 60 Hz
IEC trip class 1-45
Special Grundfos trip class 0.1 to 30 s
Voltage variation - 25 %/+ 15 % of nominal voltage
Approvals EN 60947, EN 60335, UL/CSA 508
Marking CE, cUL, C-tick
Consumption Max. 5 W
Plastic type Black PC / ABS
Measuring range Accuracy Resolution
Current without external current transformers 3-120 A ± 1 % 0.1 A
Current with external current transformers 120-999 A ± 1 % 1 A
Phase-to-phase voltage 80-610 VAC ± 1 % 1 V
Frequency 47-63 Hz ± 1 % 0.5 Hz
Power 0-1 MW ± 2 % 1 W
Power factor 0 - 0.99 ± 2 % 0.01
Energy consumption
0-4 x 10
9
kWh
± 5 % 1 kWh
IO 112 Description Product number
The IO 112 is a measuring module and a 1-channel protection unit for use in
connection with the MP 204 motor protection unit. The module can be used for
protection of pump against other factors than the electrical conditions, for
instance dry-running. It can also be used as a stand-alone protection module.
The IO 112 interface has three inputs for measured values one potentiometer for
setting of limits indicator lights indicating the
• measured value of the input
• value of the limit set
• alarm source
• pump status.
Electrical data:
• Supply voltage: 24 VAC ± 10 % 50/60 Hz or 24 VDC ± 10 %
• Supply current: Min. 2.4 A; max. 8 A
• Power consumption: Max. 5 W
Ambient temperature: -13 °F to +149 °F (-25 °C to +65 °C)
• Enclosure class: IP20
96651601