Product Manual
Table Of Contents
- 1. SQ, SQE introduction
- 2. SQ, SQE applications
- SQ with pressure switch and pressure tank
- Constant-pressure control with CU 301, residential water supply
- Constant-pressure control with CU 301, irrigation
- Maintaining a constant water table
- Emptying or filling a tank
- Pumping from one tank to another
- Setting of operating parameters
- SQE with manual speed control
- 3. Performance range
- 4. SQ, SQE installation
- 5. Sizing and selection
- 6. Cable sizing
- 7. SQ, SQE curve charts
- 8. SQ, SQE technical data
- 9. SQ, SQE construction
- 10. CU331SP variable frequency drive
- 11. Accessories
- 12. SP introduction
- 13. SP product overview
- 14. SP construction
- 15. SP operating conditions
- 16. How to read the curve charts
- 17. SP curve charts and technical data
- 4" and larger wells
- SP 5S (5 gpm)
- SP 7S (7 gpm)
- SP 10S (10 gpm)
- SP 16S (16 gpm)
- SP 25S (25 gpm)
- SP 35S (35 gpm)
- SP 45S (45 gpm)
- SP 62S (62 gpm)
- SP 77S (77 gpm)
- 6" and larger wells
- SP 85S (85 gpm)
- SP 150S (150 gpm)
- SP 230S (230 gpm)
- SP 300S (300 gpm)
- 8" and larger wells
- SP 385S (385 gpm)
- SP 475S (475 gpm)
- 10" and larger wells
- SP 625S (625 gpm)
- SP 800S (800 gpm)
- SP 1100S (1100 gpm)
- 18. SP electrical data
- 19. Accessories
- 20. Energy consumption
- 21. Cables
- 22. Friction loss tables
- 23. Grundfos Product Center
SP product overview
SQ, SQE, CU 331, and SP
13
66
Pump range
★ Figures in brackets ( ) indicate connection for pumps with sleeve.
Motor range
Direct-on-line starting is recommended up to 100 Hp.
Soft starter or autotransformer is recommended above 100 Hp.
Motors with star/delta are available from 7.5 Hp.
Motor protection and controllers
Motor protection of single-phase motors, see page 98.
Type 5S 10S 16S 25S 35S 45S 62S 77S 85S 150S 230S 300S 385S 475S 625S 800S 1100S
AISI 304 stainless steel ●● ●●●●●●●● ● ● ● ● ● ● ●
AISI 316 stainless steel ●●●●●●●● ● ● ● ● ● ● ●
AISI 904L stainless steel ● ●●●●●●●● ●
Connection ★ NPT 1" 1.25" 1.25" 1.5"
1.5"
(2")
2"
(2")
2" 2" (3") (3")
3"
(4")
3"
4"
5" 5" 6" 6" 6"
Flange connection:
Grundfos flange
5" 5" 6" 6" 6"
Motor output [Hp] 0.5 0.75 1.0 1.5 1.5 3.0 5.0 7.5 10.0 15 20 25 30 40 50 60 75 100 125 150 175 200 250
Single-phase ● ● ●●●●
Three-phase ● ● ●●●●●● ●●●●●●●●●●●●●●●
Industrial motor ●●● ● ●●●●
Rewindable motor ●● ● ●●●●●●●●●●●●●●
Steel: AISI 304 ● ● ●●●●●● ●●●●●●
Steel: AISI 304 and
cast iron
●● ● ●●●●●●●●●●●●●●
Steel: AISI 316 ●● ● ●●●●●●●●●●●●●●
Steel: AISI 904L ●●●●●● ● ●●●●●●●●●●●
Built-in temperature
transmitter in motor
●●●●●● ●●●●●●
Motor output [Hp] 0.5 0.75 1.0 1.5 1.5 3.0 5.0 7.5 10.0 15 20 25 30 40 50 60 75 100 125 150 175 200 250
MP 204 ● ● ●●●●●● ● ●●●●●●●●●●●●●●
Pt100 ●● ● ●●●●●●●●●●●●●●
Zinc anode ●●●●● ●●●●●●●●●●●●●●●
Vertical flow sleeve ● ● ●●●●●● ● ●●●●●●●●●●●●●●
Horizontal flow
sleeve
● ● ●●●● ● ● ●●●●●
SA-SPM ● ● ●●●●●
GO remote ● ● ●●●●●● ● ●●●●●●●●●●●●●●
RS-485
communication
module
● ● ●●●●●● ●●●●●●●●●●●●●●●
G100 ● ● ●●●●●● ●●●●●●●●●●●●●●●