Product Manual
Table Of Contents
- 1. SQ, SQE introduction
- 2. SQ, SQE applications
- SQ with pressure switch and pressure tank
- Constant-pressure control with CU 301, residential water supply
- Constant-pressure control with CU 301, irrigation
- Maintaining a constant water table
- Emptying or filling a tank
- Pumping from one tank to another
- Setting of operating parameters
- SQE with manual speed control
- 3. Performance range
- 4. SQ, SQE installation
- 5. Sizing and selection
- 6. Cable sizing
- 7. SQ, SQE curve charts
- 8. SQ, SQE technical data
- 9. SQ, SQE construction
- 10. CU331SP variable frequency drive
- 11. Accessories
- 12. SP introduction
- 13. SP product overview
- 14. SP construction
- 15. SP operating conditions
- 16. How to read the curve charts
- 17. SP curve charts and technical data
- 4" and larger wells
- SP 5S (5 gpm)
- SP 7S (7 gpm)
- SP 10S (10 gpm)
- SP 16S (16 gpm)
- SP 25S (25 gpm)
- SP 35S (35 gpm)
- SP 45S (45 gpm)
- SP 62S (62 gpm)
- SP 77S (77 gpm)
- 6" and larger wells
- SP 85S (85 gpm)
- SP 150S (150 gpm)
- SP 230S (230 gpm)
- SP 300S (300 gpm)
- 8" and larger wells
- SP 385S (385 gpm)
- SP 475S (475 gpm)
- 10" and larger wells
- SP 625S (625 gpm)
- SP 800S (800 gpm)
- SP 1100S (1100 gpm)
- 18. SP electrical data
- 19. Accessories
- 20. Energy consumption
- 21. Cables
- 22. Friction loss tables
- 23. Grundfos Product Center
SP curve charts and technical data
SQ, SQE, CU 331, and SP
17
96
4" and larger wells - continued
SP 62S (62 gpm) / 6 inch motor
Pump
model
Nom.
head
[ft]
Ph
Volts
[V]
Motor
[Hp]
Dimensions
Net weight
(complete)
[lb]
62S
ABCDE
TM06 4962 3415
[in. (mm)] [in. (mm)] [in. (mm)] [in. (mm)] [in. (mm)]
62S - Motor dia. 6 inch, 60 Hz, rated 62 gpm (2" NPT)
62S75-14 285
3 208-230 7.5 ▲ 76.70 (1948) 23.51 (597) 53.19 (1351) 5.50 (140) 5.50 (140) 119.3
3 460 7.5 ▲ 76.70 (1948) 23.51 (597) 53.19 (1351) 5.50 (140) 5.50 (140) 119.3
3 575 7.5 ▲ 76.70 (1948) 23.51 (597) 53.19 (1351) 5.50 (140) 5.50 (140) 119.3
62S75-17 347
3 208-230 7.5 ▲ 85.56 (2173) 23.51 (597) 62.05 (1576) 5.50 (140) 5.50 (140) 124.6
3 460 7.5 ▲ 85.56 (2173) 23.51 (597) 62.05 (1576) 5.50 (140) 5.50 (140) 124.6
3 575 7.5 ▲ 85.56 (2173) 23.51 (597) 62.05 (1576) 5.50 (140) 5.50 (140) 124.6
62S100-20 409
3 208-230 10 ▲ 95.60 (2428) 24.69 (627) 70.91 (1801) 5.50 (140) 5.50 (140) 136.4
3 460 10 ▲ 95.60 (2428) 24.69 (627) 70.91 (1801) 5.50 (140) 5.50 (140) 136.4
3 575 10 ▲ 95.60 (2428) 24.69 (627) 70.91 (1801) 5.50 (140) 5.50 (140) 136.4
62S100-22 450
3 208-230 10 ▲ 101.50 (2578) 24.69 (627) 76.82 (1951) 5.50 (140) 5.50 (140) 139.9
3 460 10 ▲ 101.50 (2578) 24.69 (627) 76.82 (1951) 5.50 (140) 5.50 (140) 139.9
3 575 10 ▲ 101.50 (2578) 24.69 (627) 76.82 (1951) 5.50 (140) 5.50 (140) 139.9
62S100-24 491
3 208-230 10 ▲ 107.41 (2728) 24.69 (627) 82.72 (2101) 5.50 (140) 5.50 (140) 143.4
3 460 10 ▲ 107.41 (2728) 24.69 (627) 82.72 (2101) 5.50 (140) 5.50 (140) 143.4
3 575 10 ▲ 107.41 (2728) 24.69 (627) 82.72 (2101) 5.50 (140) 5.50 (140) 143.4
Notes:
Control box is required for 3-wire, single-phase applications. Data does not include control box.
Performance conforms to ISO 9906. 1999 (E) Annex A. Minimum submergence is 2 feet.
▲ MS 6000C motor.
E = Maximum diameter of
pump including cable
guard and motor.
NPT