Brochure

Technical data
49
UP 15 ALPHA
Approximate power usage
Approvals
Note: Dimensions in inches unless otherwise noted.
ALPHA 15-55 F Linecord
TM04 6012 4709
ALPHA 15-55 FR Linecord
TM04 6013 4709
G
B
C
E
A
D
F
A
B
C
E
D
F
G
Flow range: 0-21.5 gpm
Head range: 0-17 feet
Motors: 2-pole, single-phase
Max. liquid temperature: 230 °F (110 °C)
Min. liquid temperature: 36 °F (2 °C)
Max. system pressure: 150 psi (10 bar)
Closed (F, FR) and Open systems (SF)
Model Volts Amps Watts Hp Capacitor
ALPHA 15-55 115 0.65 5 to 45 0.06 -
Speed setting Min. Max.
High fixed speed III 39W 45W
Medium fixed speed II 15W 30W
Low fixed speed I 5W 8W
Constant pressure 8W 45W
Constant pressure 14W 45W
Constant pressure 22W 45W
AutoADAPT 5W 45W
Canadian EMC
Standard:
ICES-003
This Class B digital
apparatus complies with
Canadian ICES-003.
Model type Product number
Dimensions [inches]
Connection type
and size
Shipping weight
[lbs]
AB C DEFG
ALPHA 15-55 F 59896877 6 1/2 6 1/2 5 1/4 3 13/16 3 11/16 3 9/16 5 3/8
GF 15/26
(2) 1/2” dia. bolt
holes
7.20
ALPHA 15-55 FR 59896878 6 1/2 7 3/16 5 1/4 3 13/16 3 11/16 3 9/16 5 3/8 7.10
ALPHA 15-55 SF 59896879 6 1/2 6 1/2 5 1/4 3 13/16 3 11/16 3 9/16 5 3/8 6.10
ALPHA 15-55 F/LC 59896832 6 1/2 6 1/2 4 15/16 4 2 1/2 3 7/16 4 1/8
GF 15/26
(2) 1/2” dia. bolt
holes
7.50
ALPHA 15-55 FR/LC 59896833 6 1/2 7 4 15/16 4 2 1/2 3 7/16 4 1/8 7.33
ALPHA 15-55 SF/LC 59896834 6 1/2 6 1/2 4 15/16 4 2 1/2 3 7/16 4 1/8 6.25
ALPHA 15-55 F/FR/SF/LC