Brochure

Technical data
50
Note: The check valve can be removed.
Dimensions in inches unless otherwise noted.
TM03 5535 0907
UPS 15-58 FC UPS 15-58 FRC
TM03 8757 2407
TM03 8531 1907
0 2 4 6 8 10 12 14 16 18 20
Q[GPM]
0
2
4
6
8
10
12
14
16
18
20
[ft]
H
1
2
3
2
1
3
Flow range: 0-17 gpm
Head range: 0-19.5 feet
Motors: 2-pole, single-phase
Max. liquid temperature: 230 °F (110 °C)
Min. liquid temperature: 36 °F (2 °C)
Max. system pressure: 145 psi (10 bar)
Model Spd Volts Amps Watts Hp Capacitor
UPS 15-58 FC/FRC
3
115
0.75 87 1/25
10μF/180 V2 0.66 80 1/25
1 0.55 60 1/25
Without check valve
With check valve
Approvals
Model type Product number
Dimensions [inches]
Connection type
and size
Shipping weight
[lbs]
ABCDEF
UPS 15-58 FC 59896341 6 1/2 5 1/4 4 4 3/16 3 3 5/32
GF 15/26 flange
(2) 1/2" dia. bolt holes
7 1/4
UPS 15-58 FRC 59896343 6 1/2 5 1/4 4 4 3/16 3 3 5/32
GF 15/26 flange
(2) 1/2" dia. bolt holes
7 1/4
UPS 15-58 FC/FRC