Brochure

Technical data
53
UP 26 Variable Speed
Variable speed models include the following
features:
Three speed control options:
1) Manual
2) Voltage: 0-10V(DC) or 2-10V(DC)
3) Current: 0-20mA or 4-20 mA
Dip switch control selection
Pump exercising
Manual offset dial
Performance indicator LED's.
Note: Dimensions in inches unless otherwise noted.
TM03 8841 2607
UP 26-64 F/VS
TM03 8533 1907
0 4 8 12 16 20 24 28 32 36 40
Q[GPM]
0
4
8
12
16
20
24
[ft]
H
b
a
a. MIN
b. MAX
a. MIN
b. MAX
Flow range: 0-34 gpm
Head range: 0-24.5 feet
Motors: 2-pole, single-phase
Max. liquid temperature: 195 °F (91 °C)
Min. liquid temperature: 36 °F (2 °C)
Max. system pressure: 145 psi (10 bar)
Model Volts Amps Watts Hp Capacitor
UP 26-64 F/VS 115 1.7 185 1/12 8μF/180 V
Approvals
Model type Product number
Dimensions [inches]
Connection type
and size
Shipping weight
[lbs]
AB C DE F
UP 26-64 F/VS 52722553 6 1/2 6 3/8 5 1/16 4 1/8 3 1/2 3 5/32
GF 15/26 flange
(2) 1/2" dia. bolt holes
11 1/4
UP 26-64 F/VS