Overview of Primary Product

Technical data
29
Note: If the UP pump is equipped with a timer, the maximum liquid tem-
perature is 150 °F (66 °C).
Note: LC/TLC Models have 6-foot 3-prong power cord.
TM03 8425 1507
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0
Q [US GPM]
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
5.5
6.0
6.5
[ft]
H
a
b
Flow range: 0-6.6 U.S. gpm
Head range: 0-6.6 feet
Motors: 2-pole, single-phase
Max. liquid temperature: 230 °F (110 °C)
Min. liquid temperature: 36 °F (2 °C)
Max. system pressure: 145 psi
Model Volts Amps Watts Hp Capacitor
UP 15-10BUC5/BUC7 115 0.22 25 1/25 2μF/400 V
Position System type Description
a Open UP 15-10BUC5
b Open UP 15-10BUC7
UP 15-10BUC5 and UP 15-10BUC5/LC UP 15-10BUC7 and UP 15-10BUC7/LC UP 15-10BUC5/TLC UP 15-10BUC7/TLC
TM03 8549 2407
TM03 8553 2407
TM03 8550 2407
TM03 8554 2407
Model type Product number A B C D E F
Connection type
and size
Shipping weight
[lbs]
UP 15-10BUC5 59896225 6 1/2 5 1/4 4 3 1/5 3 1/4 - 1/2" sweat 7.25 lbs
UP 15-10BUC5/LC 59896237 6 1/2 6 3/4 5 1/2 3 3/16 3 1/4 4 1/2" sweat 7.7
UP 15-10BUC5/TLC 59896238 6 1/2 6 3/4 5 1/2 3 3/16 3 1/4 4 1/2" sweat 7.7
UP 15-10BUC7 59896241 7 3/4 5 1/4 4 3 3/4 3 1/4 - 3/4" sweat 8.0 lbs
UP 15-10BUC7/LC 59896239 7 3/4 6 3/4 5 1/2 3 3/4 3 1/4 4 3/4" sweat 8.5
UP 15-10BUC7/TLC 59896240 7 3/4 6 3/4 5 1/2 3 3/4 3 1/4 4 3/4" sweat 8.5
UP Series
UP 15-10BUC5/7
UPSeries.book Page 29 Tuesday, September 18, 2007 1:01 PM