Overview of Primary Product

Technical data
37
Super Brute
Note: If the UP pump is equipped with a timer, the maximum liquid tem-
perature is 150 °F (66 °C).
Note: LC/TLC Models have 6-foot 3-prong power cord. Removable check valve.
TM03 8850 2607
0 2 4 6 8 10 12 14 16 18 20 22 24
Q [US GPM]
0
1
2
3
4
5
6
7
8
9
10
11
12
[ft]
H
3
2
1
Flow range: 0-21.5 U.S. gpm
Head range: 0-12 feet
Motors: 2-pole, single-phase
Max. liquid temperature: 165 °F (74 °C)
Min. liquid temperature: 36 °F (2 °C)
Max. system pressure: 145 psi
Model Spd Volts Amps Watts Hp Capacitor
UPS 15-35SUC/SFC
3
115
0.95 110 0.15
10μF/180 V2 0.75 85 0.11
1 0.06 61 0.08
Without check valve
With check valve
Position System type Description
3 Open High speed
2 Open Medium speed
1 Open Low speed
UPS 15-35SFC UPS 15-35SUC/TLC
TM03 8779 2507
TM03 8778 2507
Model type Product number A B C D E F
Connection type
and size
Shipping
weight
[lbs]
UPS 15-35SFC 59896772 6 8/16 5 8/16 4 2/16 3 14/16 2 15/16 3 2/16 GF15/26 6
UPS 15-35SUC 59896778 5 14/16 5 1/16 4 2/16 3 7/16 2 15/16 - GU125 5.4
UPS 15-35SUC/TLC 59896780 5 14/16 5 1/16 4 2/16 3 7/16 2 15/16 - GU125 6.2
UP Series
UPS 15-35SUC/SFC
UPSeries.book Page 37 Tuesday, September 18, 2007 1:01 PM