Overview of Primary Product

Technical data
45
Super Brute
Note: If the UP pump is equipped with a timer, the maximum liquid tem-
perature is 150 °F (66 °C).
Note: LC/TLC Models have 6-foot 3-prong power cord. Removable check valve.
TM03 8849 2607
0 2 4 6 8 10 12 14 16 18 20 22 24 26
Q [US GPM]
0
2
4
6
8
10
12
14
16
18
[ft]
H
3
2
1
Flow range: 0-25 U.S. gpm
Head range: 0-18 feet
Motors: 2-pole, single-phase
Max. liquid temperature: 230 °F (110 °C)
Min. liquid temperature: 36 °F (2 °C)
Max. system pressure: 145 psi
Model Spd Volts Amps Watts Hp Capacitor
UPS 15-55SFC
3
115
0.75 87 0.12 10μF/180 V
20.69770.110μF/180 V
1 0.53 58 0.08 10μF/180 V
UPS 15-55SUC
3
115
0.69 87 0.12 10μF/180 V
20.66740.110μF/180 V
1 0.31 56 0.08 10μF/180 V
Without check valve
With check valve
Position System type Description
3 Open High speed
2 Open Medium speed
1 Open Low speed
UPS 15-55SFC UPS 15-55SUC/TLC
TM03 8779 2507
TM03 8778 2507
Model type Product number A B C D E F
Connection type
and size
Shipping
weight
[lbs]
UPS 15-55SFC 59896773 6 8/16 5 8/16 4 2/16 3 14/16 2 15/16 3 2/16 GF15/26 6
UPS 15-55SUC 59896781 5 14/16 5 1/16 4 2/16 3 7/16 2 15/16 - GU125 5.4
UPS 15-55SUC/TLC 59896783 5 14/16 5 1/16 4 2/16 3 7/16 2 15/16 - GU125 6.2
UP Series
UPS 15-55SFC/SUC
UPSeries.book Page 45 Tuesday, September 18, 2007 1:01 PM