Overview of Primary Product

Technical data
54
Super Brute
Note: The check valve can be removed.
TM03 8195 2006
0 4 8 12 16 20 24 28 32 36
Q [US GPM]
0
4
8
12
16
20
24
28
[ft]
H
1
2
3
Flow range: 0-33 U.S. gpm
Head range: 0-29 feet
Motors: 2-pole, single-phase
Max. liquid temperature: 230 °F (110 °C)
Min. liquid temperature: 36 °F (2 °C)
Max. system pressure: 145 psi
Model Spd Volts Amps Watts Hp Capacitor
UPS 26-99FC
3
115
1.8 197 1/6 20μF/180 V
2 1.5 179 1/6 20μF/180 V
1 1.3 150 1/6 20μF/180 V
UPS 26-99FC/BFC
3
230
0.9 196 1/6 5μF/400 V
2 0.8 179 1/6 5μF/400 V
1 0.7 150 1/6 5μF/400 V
Without check valve
With check valve
Position System type Description
3
Closed (FC) and
open (BFC)
High speed
2
Closed (FC) and
open (BFC
Medium speed
1
Closed (FC) and
open (BFC
Low speed
UPS 26-99FC UPS 26-99BFC
TM03 8757 2407
TM03 8531 1907
Model type
Product number
ABC D E F
Connection type
and size
Shipping weight
[lbs]
115 V 230 V
UPS 26-99BFC 52722518 52722519 6 1/2 6 4 7/8 3 1/2 3 7/16 3 5/32
GF 15/26 flange
(2) 1/2" dia. bolt boles
10.3
UPS 26-99FC/BFC 52722512 52722513 6 1/2 6 4 7/8 3 1/2 3 7/16 3 5/32
GF 15/26 flange
(2) 1/2" dia. bolt boles
10.3
UP Series
UPS 26-99FC/BFC
UPSeries.book Page 54 Tuesday, September 18, 2007 1:01 PM