Submittal Sheet

Suction from a tank
1
2
3
3
6
5
7
4
TM073986
Pos. Description
1 Highest faucet
2 Isolating valve
3 Pipe support
4 Pressure tank
5 Drain to sewer
6
Strainer. A foot valve is optional. We recommend using a foot valve
together with JP PS.
7 Slight downward slope
Electrical connection
The electrical connection and protection must be carried out
in accordance with local regulations. Please also observe
the following requirements:
Make sure that the pump and pressure-control unit are
suitable for the power supply to which they are to be
connected.
The pump and pressure-control unit must always be
correctly grounded.
The plug on the pump must have the same protective
earth (PE) connection system as the power outlet. If
not, use a suitable adapter if allowed by local
regulations.
A pump without plug must be connected to an external
main switch or wired with a plug.
Motor protection
The pump incorporates current- and temperature-dependent
motor protection. If the pump is running without water, is
blocked or otherwise overloaded, the built-in thermal switch
will cut out. When the motor has cooled sufficiently, it will
restart automatically.
No external motor protection is required.
JP PS
3
10
Installation and operation