Manual

GDS-2000A Programming Manual
40
Related
Commands
:ACQuire:AVERage
Parameter
SAMPle
Sample mode sampling
PDETect
Peak detect sampling
AVERage
Average sampling mode
Example
:ACQuire:MODe PDETect
Sets the sampling mode to peak detection.
:ACQuire<X>:MEMory?
Query
Description
Returns the data in acquisition memory for the
selected channel as a header + raw data.
Syntax
:ACQuire<X>:MEMory?
Related
Commands
ACQuire:RECOrdlength
:HEADer
Parameter
<X>
Channel number (1 to 4)
Example
:ACQuire1:MEMory?
Format,2.0A;Memory
Length,5000;IntpDistance,0;Trigger
Address,2499;Trigger Level,9.400E-
02;Source,CH1;Vertical Units,V;Vertical Units
Div,0;Vertical Units Extend Div,13;Label,;Probe
Type,0;Probe,1.000e+00;Vertical Scale,5.000e-
02;Vertical Position,-9.400e-02;Horizontal
Units,S;Horizontal Scale,2.000E-04;Horizontal
Position,0.000E+00;Horizontal Mode,Main;SincET
Mode,Real Time;Sampling Period,4.000e-
07;Horizontal Old Scale,2.000E-04;Horizontal Old
Position,0.000E+00;Firmware,V0.99.03;Time,19-
Sep-12 10:04:48;Waveform Data; #510000 <Raw
Data> <LF>