Datasheet

Users can rapidly search desired waveforms according to the trigger
condition. After activating the search function, hollow inverted triangles
will show the location met the trigger condition. The upper left hand
corner Overall will show the total number of waveforms met the trigger
condition. Users can set waveform search by the trigger condition such
as Edge, pulse width, Runt, Rise/Fall, and Bus. When the trigger
condition is met, hollow inverted triangles will appear. Users can save
all marks to compare with the next input signal. The front panel of the
MDO-2000E series controls waveform zoom-out and play/pause function
to swiftly identify each desired event. The function allows users to
conveniently complete waveform search and save marks for rapid
comparison and analysis.
C.
WAVEFORM SEARCH FUNCTION
H.
POWER SUPPLY AND DMM FUNCTIONS(MDO-2000EX only)
E.
Users Can Select Analyze Segments” to Conveniently Obtain The Analysis Results.
SEGMENTED MEMORY FUNCTION
To achieve the most ideal application for memory depth, the MDO-2000E
series has the built-in segmented memory function. The segmented
memory function allows users to select the desired important signals for
observation. Hence, insignificant signals can be neglected and serial bus
decoding; pulse or inrush signals can be identified when retrieving signals.
The segmented memory function of the MDO-2000E series allows users
to select the number of sections. The maximum sections can be selected
are 29,000. After activating the function, users can select and observe
waveform for each segment by turning the Variable knob. The ultimate
application of memory depth, therefore, is completely realized.
MDO-2000EX has expanded its capabilities by incorporating a 5,000 count
DMM and a 5V/1A power supply. DMM provides tests for ACV, DCV, ACA,
DCA resistance, diode and temperature. The highly accurate DMM can
strengthen DSO's capabilities of voltage and current measurement
accuracy. Power supply provides 5V/1A; 0.1V incremental adjustment which
can supply power for the development board and IoT (Internet of Things)
module of the often used 8051/Arduino/ESP8266/MSP430 in
Microprocessors and Micro controllers experiment courses. For education
and digital circuit tests, it can satisfy the voltage input requirements of 5V
or 3.3V. Each increment is 0.1V and over load protection is available.
With respect to signal source, MDO-2000E features a built-in dual channel
25MHz arbitrary waveform generator with modulation capability and also
provides 14 bits vertical resolution; sample rate of 200MSa/s; 13 output
waveforms (Sine, Square, Pulse, Ramp, DC, Noise, Sinc, Gaussian, Lorentz,
Exponential Rise, Exponential Fall, Haversine, Cardiac); and AM/FM/FSK
modulation and sweep function. The friendly user interface is the ideal
choice for education and applications such as circuit simulation tests.
Arbitrary waveform generator provides users with 16k memory length.
Users can upload basic waveforms, including Sine, Square, Pulse, Ramp,
and Noise to edit arbitrary waveforms. Normal and Function Edit can edit
waveforms. The edited waveforms can be saved as UAW file for data access.
G.
Users, via the data log function, can observe waveform changes
in long periods of time to ensure product reliability or measure
sporadically appeared signals. The data log function, based on
the requirements, can set record time and interval. Record time
can be selected from 5 minutes to 1000 hours, and record interval
is 5 seconds, the minimum. Waveform type for record data and
CSV file format for each channel can also be selected. Data can
be stored in USB drive, the MDO-2000E series or the remote
computer via LAN.
D.
DATA LOG FUNCTION
25MHz DUAL CHANNEL ARBITRARY WAVEFORM GENERATOR
The MDO-2000E series provides the Mask function, which allows
users to apply Auto Mask and user-defined Mask to determine
whether the quality of the product meets the regulation. Via user-
defined mask, users can set up to 8 areas and each area is up to
10 points to meet test requirements. Users can also refer to the
examples from user manual to edit Mask by the PC to satisfy all
test needs. By setting Save On, users can log and monitor signals,
which violate test conditions.
F.
MASK FUNCTION