Manual

OPERATION
15
H = 2 2 . 0 m A
m AL 0= 0 0. 7 4 S = 1T
CWDA CW R I DO EM T M EI
Time setting
ACW, DCW and IR
test indicators
Ground mode
Time soft-key
High limit Low limit EDIT Status
0 00
k V
IDE
T
Am
Choose Test Function
Use the ACW, DCW or IR soft-keys to choose a
test function.
A CW D C W I R
Choose High/Low limits
Use the FIELD key to bring the cursor to the H or L
setting.
Use the scroll wheel to edit the setting.
FIELD
Test Time
Use the FIELD key to select the T setting.
Use the scroll wheel to edit the time.
Press the TIME soft-key to toggle the test time
ON/OFF. Note that the test time cannot be edited
with the scroll wheel when the test time is set to OFF.
FIELD
I M ET
Save the test settings and return to READY Status
Press the SAVE key. The current test is saved in
memory.
The tester reverts back to READY status.
SAVE