User Manual

TEST MODE FUNCTION
143
Running a Sequence
When running a sequence, the display changes
to the sequence run view.
Settings
Step X of Y
Branch 2
HOLD/CONTI test
STOP/RUN test
Readback
measurements
Branch 1
1. Press Output.
Output
2. Press RUN[F4] key. The test will start to run.
The settings of current step will be shown at the
top of the screen and the measurement readout
will be shown on the bottom of the screen.
The top-right of the screen will display the
current step number by the total number of
steps (current step/total steps).
3. The test will continue to run until the last step
has run, or Stop[F4] key is pressed. When the
test has finished/stopped, the screen will
return to the original settings screen.
4. If any of the steps have a conditional branch
configured, the branch can be manually
evoked during run time by pressing the
BRN1[F1] soft-key (branch 1) or the BRN2[F2]
soft-key (branch 2). Alternatively
the :TRIG:SEQ:SEL:EXEC command can also