Slew Rate Mode
The slew rate, which is described as the fluctuating change of
voltage per unit of time, can be customized by user in the 2 modes
containing Time and Slope elaborated below for ASR-2000 models.
1. Press the Menu key. The Menu
setting will appear on the display.
2. Use the scroll wheel to go to item 2, MISC
Configuration and press Enter.
3. Go to the Slew Rate Mode setting using the
scroll wheel and press Enter. Choose the slew
rate mode and press Enter again to confirm.
Time
Regardless of the output voltage scale,
the rising time of slew rate is definitely
no more than 100us.
Slope
The rising slew rate is constantly fixed in
1.5 V/us with varied rising time in
accord with differed output voltage scale.
4. Press Exit[F4] to exit from the
MISC Configuration settings.