User Manual

ASR-2000 Series User Manual
196
*2
For an output voltage of 100 V / 200 V, a load power factor of 1, with respect to
stepwise change from an output current of 0 A to the maximum current (or its
reverse). 10% ~ 90% of output voltage
*3
For AC mode, at an output voltage of 100 V / 200 V, maximum current, and load power
factor of 1 and sine wave only.
Model
ASR-2050
ASR-2050R
ASR-2100
ASR-2100R
Measured value display
Note:
All accuracy of the measurement function is indicated for 23 °C±5 °C.
Voltage
RMS, AVG
value*1
Resolution
0.1 V
Accuracy*2
For 45 Hz to 65 Hz and DC: ±(0.5 % of
reading + 0.3 V / 0.6 V)
For 40 Hz to 999.9 Hz: ±(0.7 % of reading +
0.9 V / 1.8 V)
PEAK value
Resolution
0.1 V
Accuracy
For 45 Hz to 65 Hz and DC: ±(|2 % of
reading| + 1 V / 2 V)
Current
RMS, AVG
value
Resolution
0.01 A
Accuracy*3
For 45 Hz to 65 Hz
and DC:
±(0.5 % of reading +
0.02 A / 0.02 A)
For 40 Hz to 999.9
Hz:
±(0.7 % of reading +
0.04 A / 0.04 A)
For 45 Hz to 65 Hz
and DC:
±(0.5 % of reading +
0.04 A / 0.02 A)
For 40 Hz to 999.9
Hz:
±(0.7 % of reading +
0.08 A / 0.04 A)
PEAK value
Resolution
0.1 A
Accuracy*4
For 45 Hz to 65 Hz
and DC:
±(|2 % of reading| +
0.2 A / 0.1 A)
For 45 Hz to 65 Hz
and DC:
±(|2 % of reading| +
0.2 A / 0.1 A)
Power
Active (W)
Resolution
0.1 / 1 W
Accuracy*5
±(2 % of reading +
0.5 W)
±(2 % of reading + 1
W)
Apparent
(VA)
Resolution
0.1 / 1 VA
Accuracy*5
*6
±(2 % of reading +
0.5 VA)
±(2 % of reading + 1
VA)
Reactive
(VAR)
Resolution
0.1 / 1 VAR
Accuracy*5
*7
±(2 % of reading +
0.5 VAR)
±(2 % of reading + 1
VAR)
Load power factor
Range
0.000 to 1.000
Resolution
0.001
Load crest factor
Range
0.00 to 50.00
Resolution
0.01