User Manual

ASR-2000 Series User Manual
62
Select the Voltage Range
Background
The Range setting determines the general outlet
voltage range. The ranges available correspond
to common mains output voltage standards.
Steps
1. Press Range to access the Range
menu.
2. Set the voltage range with the F1 ~ F4 soft-
keys.
Soft-keys
F1: AUTO
F3: 200V
F4: 100V
3. Press Enter to confirm the Range setting.
Example
Range setting
F1
F3
F4
Note
The output voltage values set by user can be
divided into 2 manual settings, both of which have
close relation with voltage range that contains high
range (200V, AUTO) and low range (100V). For
instance, when setting 5 Vrms under 200V range
and 3 Vrms under 100V range, the Vrms setting
will change from 5 Vrms to 3 Vrms directly after
switching the voltage range from 200V to 100V.
Also, if the voltage range is changed when the output
is on, the output will be automatically turned off.