User Manual

ASR-2000 Series User Manual
78
IPK Limit
On/Off
In theory, It is the function which keeps the IPK
limits (+ & -) within the certain range when the
predefined values are reached. If, however, this
function is turned off, the output will be disabled
instantly when either IPK+ or IPK- limit is reached.
IPK Limit On
4. After entering the either IPK+
Limit or IPK- Limit setting, press
F1 soft key to turn IPK Limit
function On.
IPK Limit ON:
T
Kept within IPK
Limit On Level
I
Load On
IPK Limit Off
5. After entering the either IPK+
Limit or IPK- Limit setting, press
F1 soft key to turn IPK Limit
function Off.
IPK Limit OFF:
T
IPK Limit Off Level is reached.
Turn the Output Off Immediately.
I
Load On
6. Press Enter to confirm the peak current setting.