:TEMPlate:MODe
Set
Query
Sets or returns Go-No Go test template mode.
Same as: Utility key F5 (More) F3 (Go-NoGo
Menu) F1 (Template Edit) F1 (Template)
< Long >
< Short >
:template:mode <NR1>
:template:mode?
:temp:mod <NR1>
:temp:mod?
<NR1>
Waveform used for Go-NoGo minimum
template
0
Normal template (Max and Min)
1
Auto template
:template:mode 0
:template:min 1
Select normal template
mode, then select
internal waveform W1
as Min template