GDS-1152A-U Probe
Applicable model &
probe
GDS-1152A-U
GTP-150A-2*
Position x 10 Attenuation Ratio
10:1
Bandwidth DC ~ 150MHz
Input Resistance 10M when used with 1M input
Input Capacitance
17pF approx.
Maximum Input
Voltage
500V CAT I, 300V CAT II (DC+Peak
AC)Derating with frequency
Position x 1 Attenuation Ratio
1:1
Bandwidth DC ~ 6MHz
Input Resistance 1M when used with 1M input
Input Capacitance
47pF approx.
Maximum Input
Voltage
300V CAT I, 150V CAT II (DC+Peak
AC)Derating with frequency
Operating Cond. Temperature –10°C ~ 55°C
Relative Humidity
85% @35°C
Safety Standard EN 61010-031 CAT II
* Note: GW Instek reserves the right to change the probe model type (GTP-070A-4,
GTP-100A-4, GTP-150A-2) at anytime without notice for probe model types of similar