User manual

GDS-2000A Programming Manual
112
Syntax
:TIMebase:MODe {MAIN | WINDow | XY | ?}
Parameter
MAIN
Sets the time base mode to the main
screen.
WINDow
Sets the time base mode to the zoom
window.
XY
Sets the time base mode to the XY
display.
Return parameter
Returns the time base mode (MAIN, WINDOW,
XY)
Example
:TIMebase:MODe MAIN
Sets the time base mode to the main mode.
:TIMebase:WINDow:POSition
Set
Query
Description
Sets or queries the zoom horizontal position.
Syntax
:TIMebase:WINDow:POSition {<NRf> | ?}
Related
commands
:TIMebase:MODe
Parameter
<NRf>
Horizontal position for zoom window
Return parameter
<NR3>
Returns the zoom horizontal position.
Example
:TIMebase:WINDow:POSition 2.0E-3
Sets the zoom horizontal position as 20ms.
:TIMebase:WINDow:SCALe
Set
Query
Description
Sets or queries the zoom horizontal scale.
Note
If the oscilloscope is under “ZOOM” mode, the
main timebase function will be disabled and
cannot be modified.
Syntax
:TIMebase:WINDow:SCALe {<NRf> | ?}
Related
commands
:TIMebase:MODe