User manual

COMMAND DETAILS
135
Parameter
<sting>
The number of characters in the string
depends on the data size setting. The
string must be enclosed in double
quotes, "string".
x = don’t care
1 = binary 1
0 = binary 0
Return Parameter
Returns the data value.
Example1
:TRIGger:BUS:B1:I2C:DATa:SIZe 1
:TRIGger:BUS:B1:I2C:DATa:VALue "1x1x0101"
Sets the value to XXX0101
Example 2
:TRIGger:BUS:B1:I2C:DATa:VALue?
1X1X0101
:TRIGger:BUS:B1:UART:CONDition
Set
Query
Description
Sets or queries the UART triggering condition.
Syntax
:TRIGger:BUS:B1:UART:CONDition { RXSTArt |
RXDATA | RXENDPacket | TXSTArt | TXDATA |
TXENDPacket | TXPARItyerr | RXPARItyerr | ? }
Parameter
RXSTArt
Set trigger on the RX Start Bit.
RXDATA
Set trigger on RX Data.
RXENDPacket
Set trigger on the RX End of Packet
condition.
RXPARItyerr
Set trigger on RX Parity error
condition.
TXSTArt
Set trigger on the TX Start Bit.
TXDATA
Set trigger on TX Data.
TXENDPacket
Set trigger on the TX End of Packet
condition.
TXPARItyerr
Set trigger on TX Parity error
condition.