User manual

COMMAND DETAILS
189
Example 2
:SEARCH:TRIGger:BUS:B1:UART:TX:DATa:VALue?
1X1X0101
:SEARCH:TRIGger:BUS:B1:SPI:CONDition
Set
Query
Description
Sets or queries the SPI search triggering condition.
Syntax
:SEARCH:TRIGger:BUS:B1:SPI:CONDition {SS | MISO
| MOSI | MISOMOSI | ? }
Parameter
SS
Set to trigger on the Slave Selection
condition.
MISO
Set to trigger on the Master-In
Slave-Out condition.
MOSI
Set to trigger on the Master-Out
Slave-In condition.
MISOMOSI
Set to trigger on the Master-In
Slave-Out and Master-Out Slave-In
conditions.
Return Parameter
Returns the triggering condition.
Example
:SEARCH:TRIGger:BUS:B1:SPI:CONDition MISO
Sets the SPI bus to trigger on MISO.
:SEARCH:TRIGger:BUS:B1:SPI:DATa:SIZe
Set
Query
Description
Sets or queries the number of words for SPI data
for the search function.
Note
This setting only applies when the SPI search
trigger is set to trigger on MISO, MOSI or
MISO/MOSI
Syntax
:SEARCH:TRIGger:BUS:B1:SPI:DATa:SIZe {<NR1> | ?}
Related
commands
:SEARCH:TRIGger:BUS:B1:SPI:CONDition
Parameter
<NR1>
Number of words (1 to 32).