User manual

PEL-3000 Programming Manual
104
Syntax
:PROGram:OFFTime {<NR2>[s]|OFF}
Query Syntax
:PROGram:OFFTime?
Parameter
<NR2>[s]
(0~60) Off-Time in
seconds
OFF
Turns the Off-Time off.
Return Parameter
<string>
Off-Time:<NR2>
(a time of 0.0 is equivalent
to “OFF”)
Example
:PROGram:OFFTime 1
Sets the Off-Time to 1 second.
Query example
:PROGram:OFFTime?
>Off-Time:1.0
Returns the Off-Time (1 second).
:PROGram:PFTime
Set
Query
Description
Sets or queries the Pass/Fail-Time for the selected
step number.
Syntax
:PROGram:PFTime {<NR2>[s]|OFF}
Query Syntax
:PROGram:PFTime?
Parameter
<NR2>[s]
(0 ~ (On-time + Off time -
0.1)) (in seconds)
OFF
Turns the P/F-Time off.
Return Parameter
<string>
P/F-Time:<NR2>
Example
:PROGram:PFTime 1
Sets the P/F-Time to 1 second.
Query example
:PROGram:PFTime?
> P/F-Time:0.0
Returns the P/F-Time (1 second).
:PROGram:STIMe
Set
Query
Description
Sets or queries the Short-Time for the selected step
number.