User manual

COMMNAND OVERVIEW
109
:NSEQuence
Set
Query
Description
Configures the parameters for the Normal
Sequence. This remote command is equivalent to
the all the settings in the “Timing Edit for Normal
Sequence” menu when entering the
FUNC>Sequence>Normal Sequence menu.
Syntax
:NSEQuence
{ <NR1>,<NR1>,<string>,CC|CR|CV|CP,ILVL|IMVL|IH
VL|ILVH|IMVH|IHVH,<NR1>|INFinity,<bool>|OFF|ON
,<NR2>,<NR1>|OFF}
Query Syntax
:NSEQuence?
Related
Commands
:NSEQuence:STATe
Parameter
Parameter in order:
Description
<NR1>
Starting sequence number
<NR1>
Current sequence number
<string>
Memo message. (need to
enclose in quotes)
CC|CR|CV|CP
Mode
ILVL|IMVL|IHVL|ILVH|IMV
H|IHVH
Range
<NR1>|INFinity
Sets the loop number
<bool>|ON|OFF
Last Load 0=Off, 1=On.
Sets the load condition
after the end of the
sequence.
<NR2>
Last value: Sets the value
of the load condition if
Last Load = On
<NR1>|OFF
Chain: Sets the next
sequence in the chain.