User manual
Table Of Contents
- INTERFACE OVERVIEW
- COMMNAND OVERVIEW
- Command Syntax
- Command List
- Common Commands
- Trigger Commands
- Input State Commands
- Measurement Commands
- Configure Subsystem Commands
- Parallel Commands
- Step Resolution Commands
- External Control Commands
- Mode Subsystem Commands
- Current Subsystem Commands
- Resistance Subsystem Commands
- Voltage Subsystem Commands
- Power Subsystem Commands
- Function Commands
- Utility Commands
- File Commands
- SCPI Register Commands
- Status Registers
- Error Messages
PEL-3000 Programming Manual
122
Query example
:FSEQuence:TBASe?
>Time Base:0.30000
Returns the time base.
:FSEQuence:LLOad
Set
Query
Description
Sets or queries the Last Load state.
Syntax
:FSEQuence:LLOad {<bool>ON|OFF}
Query Syntax
:FSEQuence:LLOad?
Parameter
ON, 1
Turns Last Load on.
OFF, 0
Turns Last Load off.
Return Parameter
<string>
Last Load:ON|OFF
Example
:FSEQuence:LLOad ON
Turns Last Load on.
Query example
:FSEQuence:LLOad?
>Last Load: ON
Returns the last load state.
:FSEQuence:LAST
Set
Query
Description
Sets or queries the value of Last Load when Last
Load = ON.
Syntax
:FSEQuence:LAST{<NR2>}
Query Syntax
:FSEQuence:LAST?
Parameter
<NR2>
Current value(CC), resistance
value(CR), voltage value(CV), power
value(CP).
Return Parameter
<string>
Last:<NR2>
Example
:FSEQuence:LAST 1.000
Sets the value of Last Load to 1.000.
Query example
:FSEQuence:LAST?
>Last: 1.000
Returns the value of Last Load.