MINIMUM or MIN
MAXIMUM or MAX
LIMIT or LIM
Minimum current limit
value.
MAXimum current limit
value.
Limit the load
LOFF
Turn the load off
Return parameter
Returns a string with OCP setting followed by the OCP
value.
Example1
:OCP LIM
Sets the OCP setting to limit.
Example2
:OCP 77.000
Sets the OCP value to 77A.
Query example
:OCP?
>LIMIT, 77.000
The OCP setting is LIMIT and the OCP value is
77.000A.
[:CONFigure]:OPP
Set
Query
Description
Sets or queries the OPP trip settings. The OPP limit
can be set to a specific value or the trip setting can
be set to either limit the power or to turn the load
off.
Syntax
[:CONFigure]:OPP {<NRf> [W] | MINimum |
MAXimum | LIMit | LOFF }
Query Syntax
[:CONFigure]:OPP?
Parameter
<NRf>[W]
Power limit value.
MINIMUM or MIN
MAXIMUM or MAX
LIMIT or LIM
MINIMUM power limit
value.
MAXIMUM power limit
value.
Limit the load
LOFF
Turn the load off
Return parameter
Returns a string with OPP setting followed by the OPP
value.