User manual
Table Of Contents
- INTERFACE OVERVIEW
- COMMNAND OVERVIEW
- Command Syntax
- Command List
- Common Commands
- Trigger Commands
- Input State Commands
- Measurement Commands
- Configure Subsystem Commands
- Parallel Commands
- Step Resolution Commands
- External Control Commands
- Mode Subsystem Commands
- Current Subsystem Commands
- Resistance Subsystem Commands
- Voltage Subsystem Commands
- Power Subsystem Commands
- Function Commands
- Utility Commands
- File Commands
- SCPI Register Commands
- Status Registers
- Error Messages
PEL-3000 Programming Manual
94
Related
Commands
:POWer:LEVel
Parameter
<NRf>[ W ]
“Set” power value
MINIMUM or MIN
Minimum power level
MAXIMUM or MAX
Maximum power level
Return parameter
<NR2>
Returns the “Set” power
value.
Example
:POWer:SET MIN
Sets the power value to the minimum.
Query example
:POWer:SET?
>10W
Returns the “Set” power setting.
:POWer:LEVel
Set
Query
Description
Sets or queries the CP mode % level (percentage of
the Set power value) when the dynamic mode
units are set to Percent.
Syntax
:POWer:LEVel {<NRf> | MINimum | MAXimum }
Query Syntax
:POWer:LEVel?
Related
Commands
:POWer:Set
Parameter
<NRf>
“% level” power value
MINIMUM or MIN
Minimum % power level
MAXIMUM or MAX
Maximum % power level
Return parameter
<NR2>
Returns the “% level”
current value.
Example
:POWer:LEVel MIN
Sets the % level power value to the minimum.
Query example
:POWer:LEVel?
>50
Returns the “% Level” as 50 percent.