PEL-3000 Programming Manual
112
:NSEQuence:MODE
Set
Query
Description
Sets or queries the mode used for the normal
sequence.
Syntax
:NSEQuence:MODE {CC|CR|CV|CP}
Query Syntax
:NSEQuence:MODE?
Parameter
CC
Constant current mode
CR
Constant resistance mode
CV
Constant voltage mode
CP
Constant power mode
Return Parameter
<string>
Mode: CC|CR|CV|CP
Example
:NSEQuence:MODE CC
Sets the mode to CC.
Query example
:NSEQuence:MODE?
>Mode: CC
Returns the mode.
:NSEQuence:RANGe
Set
Query
Description
Sets or queries the range used for the normal
sequence.
Syntax
:NSEQuence:RANGe
{ ILVL|IMVL|IHVL|ILVH|IMVH|IHVH }
Query Syntax
:NSEQuence:RANGe?
Parameter
ILVL
Low I range, low V range
IMVL
Middle I range, low V range
IHVL
High I range, low V range
ILVH
Low I range, high V range
IMVH
Middle I range, high V range
IHVH
High I range, high V range
Return Parameter
<string>
Returns the range in the following
format:
Range: ILVL