User manual

PEL-3000 Programming Manual
116
Return parameter
<string>
Returns the settings for
the Data Edit for Normal
Sequence menu:
Step: <NR1>/<NR1>,
Value: <NR1>, Time:
<NR1>H: <NR1>M:
<NR1>S: <NR1>ms,
LOAD:ON|OFF, TRIG
OUT:ON|OFF, RAMP:
ON|OFF, PAUSE: ON|OFF
Example
:NSEQuence:EDIT 3,12,0.1,0,1,0,0,ON,OFF,OFF,ON
Configures the Data Edit for Normal Sequence menu
to the settings shown below.
Query example
:NSEQuence:EDIT?
> Step:3/12, Value:0.10000, Time:0H:0M:1S:0ms,
LOAD:ON, TRIG OUT:OFF, RAMP:OFF, PAUSE:ON
:NSEQuence:EDIT:POINt
Set
Query
Description
Sets or queries the current point in the sequence.
Syntax
:NSEQuence:EDIT:POINt {<NR1>}
Query Syntax
:NSEQuence:EDIT:POINt?
Related
Commands
:NSEQuence:EDIT:END?
Parameter/
Return parameter
<NR1>
1~1000*. The current point in the
sequence. *Depends on the number
of steps in the sequence.
Example
:NSEQuence:EDIT:POINt 10
Sets the current point to 10.
Query example
:NSEQuence:EDIT:POINt?
>10
Returns the current point in the sequence.