PEL-3000 Programming Manual
86
Query example
:CURRent:T1?
>0.200
Returns the T1 timer time as 200ms.
:RESistance:T2
Set
Query
Description
Sets the T2 timer settings for the CR dynamic
mode.
Syntax
:RESistance:T2 {<NRf>[s] | MINimum | MAXimum}
Query Syntax
:RESistance:T2?
Related
Commands
:RESistance:T1
Parameter
<NRf>[s]
T2 timer setting in
seconds
MINIMUM or MIN
Minimum time
MAXIMUM or MAX
Maximum time
Return parameter
<NR2>
Returns the T2 timer time
in seconds.
Example
:RESistance:T2 0.200
Sets the T2 timer time to 200ms.
Query example
:RESistance:T2?
>0.200
Returns the T2 timer time as 200ms.
:RESistance:FREQuency
Set
Query
Description
Sets the CR dynamic mode switching frequency.
This command along with the
“:RESistance:DUTY” command is used when the
dynamic time setting is set to “Freq./Duty”.
This command is only applicable for dynamic
mode.
Syntax
:RESistance:FREQuency {<NRf> | MINimum |
MAXimum}