User manual
PSU Programming Manual
44
F-76 = 00~31
Set the address of each slave to
a unique address identifier
7. Multiple units can now be operated at the same
time, see the function check below for usage
details.
Serial link cable
with RJ-45
shielded
connectors from
PSU-232 or PSU-
485 connection
kit
8 Pin Connector (IN)
8 Pin Connector (OUT)
Pin No.
Name
Pin No.
Name
Housing
Shield
Housing
Shield
1
SG
1
SG
6
TXD -
6
TXD -
3
TXD +
3
TXD +
5
RXD -
5
RXD -
4
RXD +
4
RXD +
Multi-Unit Function Check
Functionality
check
Invoke a terminal application such as Realterm.
To check the COM port No, see the Device
Manager in the PC. For WinXP; Control panel
→ System → Hardware tab.
Below shows an example using the TDK
GENESYS legacy commands.
TDK Query
When using the TDK GENESYS legacy
commands, each unit can be individually
controlled using the unique address identifiers.
For this function check, we will assume that the
master unit is assigned to address 8, while a
slave is assigned address 11.