User manual

REMOTE CONTROL
49
Sockets Server Configuration
Configuration
This configuration example will configure the
PSU socket server.
The following configuration settings will
manually assign the PSU an IP address and
enable the socket server. The socket server port
number is fixed at 2268.
1. Connect an Ethernet cable from the
network to the rear panel Ethernet
port.
LAN
2. Press the Function key to enter the
Normal configuration settings.
Page 21
Set the following LAN settings:
F-36 = 1
Enable LAN
F-37 = 0
Disable DHCP
F-39 = 172
IP Address part 1 of 4
F-40 = 16
IP Address part 2 of 4
F-41 = 5
IP Address part 3 of 4
F-42 = 133
IP Address part 4 of 4
F-43 = 255
Subnet Mask part 1 of 4
F-44 = 255
Subnet Mask part 2 of 4
F-45 = 128
Subnet Mask part 3 of 4
F-46 = 0
Subnet Mask part 4 of 4
F-43 = 172
Gateway part 1 of 4
F-44 = 16
Gateway part 2 of 4
F-45 = 21
Gateway part 3 of 4
F-46 = 101
Gateway part 4 of 4
F-57 = 1
Enable Sockets