User manual
PSU Programming Manual
80
Parameter
OFF | 0
Turns the OCP off.
ON | 1
Turns the OCP on.
Return parameter
<bool>
Returns the over current protection state in
<bool> format.
Example
SOUR:CURR:PROT:STAT OFF
Turns OCP off.
[:SOURce]:CURRent:PROTection:TRIPped
Set
Query
Description
Returns the state of the current protection circuits.
Query Syntax
[:SOURce]:CURRent:PROTection:TRIPped?
Return parameter
<bool>
Returns protection status.
Example
SOUR:CURR:PROT:TRIP?
>0
The protection circuit has not been tripped.
[:SOURce]:CURRent:SLEW:RISing
Set
Query
Description
Sets or queries the rising current slew rate. This is
only applicable for CC slew rate priority mode.
Syntax
Query Syntax
[:SOURce]:CURRent:SLEW:RISing
{<NR2>(A)|MINimum|MAXimum}
[:SOURce]:CURRent:SLEW:RISing?
Parameter
<NR2>
Per step is Rated Current divided by 100 ms.
MIN
Minimum rising current slew rate.
MAX
Maximum rising current slew rate.
Return parameter
<NR2>
Returns the step current in amps.
Example
SOUR:CURR:SLEW:RIS?
0.950
Sets the rising current slew rate to 0.950 A/ms.