Pre-installed nail easily installs in regular lumber,
engineered lumber and laminated beams
Safety and guidance system prevents nail
snagging, ensures smooth straight nail
penetration and allows bar hangers to be easily removed if necessary
Automatic levelling flange aligns the housing and lets you
hold the housing in place with one hand while driving nails
Five additional mounting points
Mounting point on top for hanger wire connection
Integral T-bar clips snaps onto T-bars - no additional clips required
H5 & H7 housings feature a pre-installed gasket
in an Air-Tite housing that limits airflow between
unconditioned areas and conditioned spaces
Standard recessed housings may allow up to
5.0 cubic ft. per minute of air leakage into
unconditioned spaces
Air-Tite fixtures are test certified to the American
Society for Testing and Materials procedure ASTM
E283 as having an air leakage rate not more than
2.0 cfm (0.944 L/s) when tested at a 1.57 psf (75 Pa)
pressure differential
Meets codes that require a gasket between
a recessed housing and ceiling. Additional
benefits include: Savings in HVAC bills, preventing moisture
damage to attic areas, reduced sound transmission between
floors, and eliminating drafts for greater comfort.
Gasket GA-ATH5-6PK and GA-ATH7-6PK are available
for covering gaps on the finished ceiling aperture (See specialty
products and accessories section)
Full-size remodel junction box
(7) 1/2" conduit (flex) pry-outs
(4) Non-Metallic (NM) cable pryouts
Allow metallic and non-metallic sheathed cable to be installed
cULus Listed 17 in
3
box volume, listed for (4) No. 12 AWG
through branch circuit 90° C conductors
Patented Got Nail!
Hanger Bracket
Air-Tite
Code Compliant
Remodel Junction Box - Full Access
Full-size junction box
(3) Slide-N-Side
wire traps allow
non-metallic (NM) sheathed cable
to be installed without tools or without
removing knockouts
Allows wiring connections to be made outside the junction box
Simply insert the cable directly into the trap after
connections are made
Accommodates the following standard non-metallic (NM)
sheathed cable types for both U.S. and Canada:
(US) #14/2, #14/3, #12/2, #12/3
(Canada) #14/2, #14/3, #12/2
(7) 1/2" conduit pry-outs accommodate straight conduit runs
cULus Listed 26 in
3
box volume, listed for through-branch
(8) No. 12 AWG branch circuit 90° C conductors through the box
Patented Slide-N-Side
Junction Box
(4) Remodel spring clips secure housing to finished ceiling
Allow installation in standard 1/2" and 5/8" ceiling material
Single arm design allows box to pass through the ceiling aperture
Flexible arm can bend or flex side-to-side around obstructions
Integral flange secures fixture against the ceiling
UL 1598 Luminaires
Designed and manufactured to Underwriters Laboratories
Standard for Safety – UL 1598
Luminaires additionally comply with National Electric Code (NEC), NFPA70
Remodel Springs
Remodel Single-Arm Design
Remodel Flange
cULus Listed
11
10
9
8
7
61
3
(3) 4-Port push-in wire nuts included
Speeds installation and increases reliability
Simply strip and insert supply wires
No additional wire nuts required
Quick Connect
Push Wire Nuts
4
q-Channel bars feature an unique
inverted “q” interlocking channel for
rigidity and stability
Pass-N-Thru
allows the bars to pass
through each other for tool-less shortening
in tight spots less than 12" without
removing from the plaster frame. Push bars
together and flex at score hole break points
Housing positions at any point within
24" joist span
Bar hangers may be repositioned 90°
on the frame on select housings
2
Patented q-Channel Bars with Pass-N-Thru
(1) Locking screws accessible from below the ceiling
Universal screw head (hex, slot or Phillips)
(6) Additional bar crimping points
Universal Locking Screw
5
H5 (5") & H7 (6") Housing Installation Features
Halo Recessed Lighting