EATON Halo Product Catalog 3" Recessed Downlighting
3-16
3
INCH
H3 Series – Low Voltage MR16 Non-IC Housing
Housing
Formed of CRS with white powder coat finish
Remodel Plaster Frame
“Easy clip” provided to secure plaster frame in ceiling
while installation is being completed. Adjustable cam-locks
provide positive lock of housing to plaster frame to complete
housing installation.
Includes:
Air-Tite
code compliant (Details Pg. 7)
Quick Connect
push wire nuts (Details Pg. 7)
Transformer
Integral 120/277V dual-tap magnetic transformer steps
line voltage down to 12V nominal MR16 lamp operating
voltage. Rated for 50W max. Housing ships as 277V model
with 120V transformer wire lead capped. For use in 120V
systems, simply cap the 277V wire lead and use 120V lead
(refer to instructions supplied with housing).
Socket
GU5.3 socket for 12V MR16 lamps
Compliances
cULus Listed 1598 luminaire
cULus Listed damp location
cULus Listed for wet location,
covered ceiling, with select trims
Air-Tite code compliant. Certified under ASTM E283;
not exceeding 2.0 cfm (0.944 L/s) air leakage rate
tested at a 1.57 psf (75 Pa) pressure differential
RoHS compliant
3" Non-IC, Air-Tite, Shallow Remodel, 120/277V – 12V
Low Voltage, MR16
H36LVRTAT277 is a Non-IC, Air-Tite
housing for use with H3
3" series trims. For installation from below the ceiling. Housing
is Air-Tite to restrict airfl ow between conditioned spaces and
unconditioned areas. H36LVRTAT277 features integral 120/277
dualtap transformer. For use with 12V MR16 lamps. Designed for
installation in 120 or 277V electrical systems.
Non-IC housing is Air-Tite
but insulation must be kept 3 inches
away from all sides of housing.
Special Features
Air-Tite
code compliant
Quick Connect
push wire nuts
H36LVRTAT277
Features
Cut hole in ceiling using
template supplied
Insert plaster frame
into ceiling opening
Support clip keeps plaster
frame in place during rest
of installation
Insert housing into
position and align slots
in housing wall with
indicator label on inside
of plaster frame opening
(bottom of cam lock
spring blades should be
positioned on flat area of
the plaster frame). Then
secure in position with
cam locks.
Install lamp and insert
trim to complete
installation
Bring power to fixture
using non metallic
sheathed cable or
flexible metal cable
(per local code)
The Slide-N-Side
wire
trap lets you make all
wiring connections
outside the junction box
Slide cable into
Slide-N-Side
wire
trap and close
junction box cover
Remodel Housing Installation
H36LVRTAT277
3-3/4"
[95mm]
Ceiling opening to match
template supplied
5"
[127mm]
1/2"
[13mm]
3-5/8"
[92mm]
10-1/2"
[267mm]
Compatible Trims
3001
3002
3003
3004
3006
3007
3008
3009
3010
3011
3012
3013
3017
3020