Product Brochure
4
INCH
Specifi cations, compliances and dimensions subject to change without notice
EATON Halo Product Catalog 4" Recessed Downlighting
4-33
Low Voltage MR16 IC Housing
H1499ICAT
1/2"
[13mm]
4-1/2"
[114mm]
Ceiling opening
7-3/8"
[187mm]
7-1/8"
[181mm]
9-1/2"
[241mm]
12-1/2"
[318mm]
4" IC, Air-Tite, New Construction, 120V – 12V
Low Voltage, MR16
H1499ICAT housing features an integral low voltage magnetic
transformer that supplies 12 volts to MR16 lamps. The H1499ICAT
is for installations where the housing will be in direct contact
with insulation*. Air-Tite
™
housing designed to restrict air fl ow
between conditioned spaces and unconditioned areas.
H1499ICAT
Features
Housing
•
Double wall aluminum construction
for greater heat dissipation
•
Designed for insulated ceilings in direct contact
with insulation* (May also be installed in
non-insulated ceilings)
Plaster Frame
•
Galvanized steel die-formed construction
•
The inner housing can be removed from plaster
frame to provide access to the junction box
•
Plaster frame features include:
• Regressed locking screw positioned for securing
hanger bars from below the ceiling
• Cutouts for easily crimping hanger bars in position
• Air-Tite aperture gasket is pre-installed
• Halo identity embossed on plaster frame
Includes:
•
Got Nail!
™
bar hangers (Details Pg. 7)
•
Pass-N-Thru
™
bars (Details Pg. 7)
•
Slide-N-Side
™
junction box wire traps (Details Pg. 7)
•
Quick Connect
™
push wire nuts (Details Pg. 7)
•
Air-Tite
™
code compliant (Details Pg. 7)
Socket
GU5.3 socket with reflector plate for bi-pin
12V MR16 lamps
Thermal Protector
Self resetting thermal protector deactivates fixture
if overheating occurs due to improper lamping
Transformer
Integral 120V magnetic transformer steps line voltage down
to 12V lamp operating voltage. For MR16 lamps up to 50W.
Compliance
•
cULus Listed 1598 luminaire
•
cULus Listed damp location
•
cULus Listed for wet location,
covered ceiling, with select trims
•
cULus Listed for feed through
•
cULus Listed for direct contact with
insulation* and combustible material
•
Air-Tite code compliant. Certified under ASTM E283;
not exceeding 2.0 cfm (0.944 L/s) air leakage rate
tested at a 1.57 psf (75 Pa) pressure differential
*Not to be used in direct contact with spray foam insulation
(consult NEMA LSD57-2013)
Compatible Trims
1419
1420
1421
1453
1493
1495
1496
1497
1498
1945
1946
1951
Special Features
Got Nail!
™
bar hangers
Pass-N-Thru
™
bars
Slide-N-Side
™
junction box
Quick Connect
™
push wire nuts
Air-Tite
™
code compliant