Instructions / Assembly

Possible Cause Corrective Action
1. Power is off. 1. Make sure power supply is on.
2. Faulty switch. 2. Test or replace switch.
3. Faulty wire connection. 3. Check wiring.
4. Damaged or defective driver. 4. Replace the driver.
Fuse blows or circuit breaker
trips when light is turned on.
1. Crossed wires or power wire is
grounding out.
1. Check wire connections.
Light will not turn on.
TROUBLESHOOTING:
PRODUCT MAINTENANCE:
1. To clean the outside of the fixture, use a dry or slightly dampened clean cloth
(use clean water, never a solvent) to wipe the surface of the fixture.
2. To clean the inside of the fixture, first disconnect power to the fixture by
turning off the circuit breaker or by removing the fuse at the fuse box. Next,
use a dry or slightly dampened clean cloth (use clean water, never a solvent) to
wipe the interior surface of the fixture.
3. Do not use any cleaners with chemicals, solvents or harsh abrasives. Use only
a dry soft cloth to dust or wipe carefully.
DRIVER REPLACEMENT:
This product is ENERGY STAR® listed. The driver can be replaced without
having to cut wires. Please contact a qualified electrician if driver replacement is
needed.
Page 9
Class 2 Power Supply
Dimmable Constant Current
CDL
Model: JWM024W-0700-36
Input Voltage: 120Vac
Input Current: 0.22A
Frequency: 60Hz
PF: >0.9
Suitable for operation with main supply dimmer
tc
Red: +
Black: -
E362575
RoHS
SELV
Equiv.
L: Black
N: White
Output Current: 700mA
Max. Output Power: 24W
Max. Output Voltage: 36Vdc
Max. Case Temp t
c
=70°C
Max. Operating Temp=40°C