User's Guide

Table 2
Ethernet Port Pinout
Connector
Pin
Signal
Name
PoE
1
2
3
4
5
6
7
8
1
RJ45_DA+
PoE-
2
RJ45_DA–
PoE-
3
RJ45_DB+
PoE+
4
RJ45_DC+
PoE+
5
RJ45_DC–
PoE+
6
RJ45_DB–
PoE+
7
RJ45_DD+
PoE-
8
RJ45_DD–
PoE-
Table 3
Console Port Pinout
Connector
Pin
Signal Name
Function
1
2
3
4
5
6
7
8
3
TXD
Transmit
4
GND
Ground
5
GND
Ground
6
RXD
Receive
Pins not listed are not connected.
Table 4
RS-485 Port Pinout
Connector
Pin
Signal Name
Function
1
2
3
4
5
6
7
8
1
RS485_B
Data-
2
RS485_A
Data+
4
GND
Ground
5
GND
Ground
7
PSE_12V
12V+ OUT
8
PSE_12V
12V+ OUT
Pins not listed are not connected.
Note: The serial console port allows you to connect the AP to a
serial terminal or a laptop for direct local management. This port
is an RJ-45 female connector with the pinouts described in Table 3.
Currently for use by Service & Support only.
Note: The RS-485 port allows you to connect the AP to a RS-485
terminal. The maximum allowable current of PSE 12V power output
is 300mA. In addition, PSE 12V power output can be turned on and
off by software. This port is an RJ-45 female connector with the
pinouts described in Table 4.
Power
The AP311 series access point supports direct DC power adapter (48V
DC nominal, sold separately) and Power over Ethernet (PoE).
The DC power connector port is located on the back of the device, as
shown in Figure 3.
The PoE allows the Ethernet port to draw power from an IEEE
802.3at compliant source.
HAN Access Point supports the power adapter provided by HAN ONLY.
Before You Begin
Refer to the sections below before beginning the installation process.
Pre-installation Checklist
Before installing your AP311 Stellar access point, be sure that you
have the following items:
8-conductor, CAT5 or better UTP cable of required length.
One of the following power sources:
IEEE 802.3at compliant Power over Ethernet (PoE) source
(PoE switch or PoE injector).
AC-DC adapter (sold separately)output voltage DC 48V,
output current 0.6A
A terminal or a notebook
Identifying Specific Installation Locations
You can mount the HAN Access Points on a ceiling rail or on a wall.
You should first determine the location of the installation. The
installation position is located at the center of the required
coverage area and should be free from obstructions or obvious
sources of interference.
Minimize the number of obstructions (such as walls) between the
AP and user terminals.
Electronic equipment or devices (such as microwave ovens) which
may produce radio frequency noise should be away from the
installation position of the AP.
It is strictly prohibited to install around stagnant water, water seepage,
leakage or condensation. Avoid cable condensation or water seepage
along the cables connecting to the AP.
AP Installation
Refer to mounting kits installation Guide.
Verifying Post-Installation Connectivity
The LED on the AP can be used to verify that the AP is receiving power
and initializing successfully.
Product Specifications
AP311 series Dimensions/Weight
Unboxed AP311:
Net Weight: 1.64lbs / 0.74kg
Dimensions (HxWxD): 7.1 inches x 7.1 inches x 1.42 inches
(18 cm x 18cm x 3.6cm)
Environmental
Operating :
Temperature: 0°C to +50°C (+32°F to +122°F)
Humidity: 10% to 90% non-condensing
Storage and transportation :
Temperature: -40°C to +70°C(-40°F to +158°F)
For additional specifications on this product, please refer to the
Datasheet.
HAN Access Point
AP311 Regulatory Compliance and Safety
Information
xxxxxx-xx Rev. A
*xxxxxx-xx Rev. A*
Introduction
This document contains domestic and international regulatory compliance
information for the access point. To ensure that this device complies with the
regulatory standards for your region, please refer to the content below.
FCC Part 15:
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generate, uses and can
radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation.
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate this
equipment.
RF exposure warning
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment.
This product may not be collocated or operated in conjunction with any other
antenna or transmitter
This equipment must be installed and operated in accordance with provided
instructions and the antenna(s) used for this transmitter must be installed to
provide a separation distance of at least 20 cm from all persons and must not be
collocated or operating in conjunction with any other antenna or transmitter.
California Proposition 65 Warning
WARNING: This product contains chemicals known to the State of California to
cause cancer and birth defects or other reproductive harm.