ITEM #1596996 FAIRWIND HUGGER LED CEILING FAN MODEL #FWH60BNK3LRS Español p. 18 ATTACH YOUR RECEIPT HERE APPROVED FOR USE IN DAMP LOCATIONS Purchase Date Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-527-1292, 8:30 a.m. - 5 p.m., CST, Monday - Friday.
TABLE OF CONTENTS Safety Information ................................................................................................................2 Package Contents ................................................................................................................4 Hardware Contents ...........................................................................................................................5 Preparation ...........................................................................
SAFETY INFORMATION WARNING To reduce the risk of fire, electrical shock or personal injury, mount fan to outlet box marked "ACCEPTABLE FOR FAN SUPPORT OF 35 LBS. OR LESS" and use mounting screws provided with the outlet box. Most outlet boxes commonly used for the support of lighting fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
PACKAGE CONTENTS A B L C D M I E J F K G H PART G H I J K PART DESCRIPTION QUANTITY A Mounting Plate 1 B Mounting Plate Screw/Washer 4 (preassembled) C Ring 1 D Motor Housing 1 E F Motor Plate Screw (preassembled) 3 Fitter Plate 1 L M IMPORTANT REMINDER: You must use the parts provided with this fan for proper installation and safety.
HARDWARE CONTENTS (shown actual size) AA BB Wire Connector Motor Screw/Washer Qty. 3 + 1 extra Qty. 6 + 1 extra PREPARATION Before beginning assembly of product, make sure all parts are present. Place motor on carpet or on foam to avoid damage to finish. Compare parts with package contents list and hardware contents list. If any part is missing or damaged, do not attempt to install, operate or assemble the product.
INITIAL INSTALLATION 2. This fan can be mounted as a flushmount on a regular (no-slope) ceiling only. Check to make sure blades (I) will be at least 30 inches from any obstruction and at least 7 ft. above the floor. 2 30 in. min. I 7 ft. min. 3. Remove mounting plate screw/washer (B) on outer edge of mounting plate (A) that is closest to the J-hook. Remove mounting plate screw/washer (B) on outer edge of mounting plate (A) directly opposite the one was just removed.
INITIAL INSTALLATION 5. With wider opening facing up, place ring (C) over top of motor housing (D). Allow ring (C) to rest on top of motor, proceed to step 6. 5 C D 6. Lift motor housing (D) to mounting plate (A). Hang motor housing (D) on J-hook on underside of mounting plate (A). [IMPORTANT: Use one of the non-slotted holes on the rim of the motor housing to do so.] This will allow motor housing (D) to hang out of the way while wiring.
WIRING 1. Make the necessary wiring connections for remote control operation as detailed below and in the figure. For each wire connection, use one of the wire connectors (AA), (L), making sure to screw wire connector on in a clockwise direction. 1 WHITE SUPPLY WIRE BLACK SUPPLY WIRE GROUND (GREEN OR BARE) GROUND (GREEN OR BARE) BLUE WHITE WHITE CAUTION: Assistance from another person is recommended for this step.
FINAL INSTALLATION 1. Remove motor housing (D) from J-hook. Gently slide remote control receiver (M) flat-side up into top of motor housing (D), pushing wires, wire connectors and antenna within. 1 Antenna M NOTE: The remote control included with this fan meets the following requirements: a. Electrical rating: 120V / 60 Hz; motor amps:1.00 MAX. b. MAX light watts: 190W (incandescent, CFL or LED bulbs.
FINAL INSTALLATION 4. CAUTION: To reduce the risk of serious bodily injury, DO NOT use power tools to assemble the blades (I). If overtightened, blades (I) may crack and break. 4 Place one blade plate (J) under blade (I), aligning holes. Then, insert one motor screw/washer (BB) into one of the holes at the end of the blade (I), turning until the motor screw/washer (BB) comes through the other side of the blade (I). Repeat with the other motor screw/washer (BB).
FINAL INSTALLATION 6. Partially loosen two fitter plate screws (K) on the underside of the fitter plate (F) and remove the other fitter plate screw (K). 6 D F K 7. Connect WHITE wire from LED light kit (G) to WHITE wire from motor housing (D). Connect BLUE wire from LED light kit (G) to BLUE or (BLACK) wire from motor housing (D). Make sure molex connections snap together securely. K 7 D WHITE BLUE (or BLACK) WHITE BLUE G 8.
FINAL INSTALLATION 9. Align slots on shade (H) with protrusions on underside of fitter plate (F). Turn shade (H) clockwise until it no longer turns. NOTE: Pull down gently on shade (H) to make sure it is secured completely. 9 F Protrusion Slot H 10. If you wish to use the remote control bracket from remote pack (L), install screws from remote pack (L) through bracket and into the desired installation site. The remote control transmitter from remote pack (L) rests inside the bracket.
OPERATING INSTRUCTIONS CAUTION: The remote control transmitter can be programmed to multiple receivers or fans. If this is not desired, turn wall switch off to any other programmable receiver or fan. FCC Compliance Notice for Remote Control Modifications not approved by the party responsible for compliance could void the user's authority to operate the equipment. *NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
OPERATING INSTRUCTIONS 2. Restore electrical power. Within 30 seconds of restoring electrical power, press and hold the “0” button on the remote control transmitter for 5 seconds or until light on the fan blinks twice. Use the remote control transmitter to test the light and fan functions to confirm the learning process is complete. 2 NOTE: Remove protective covering from front of remote control transmitter and discard.
OPERATING INSTRUCTIONS 4. Use the fan reverse switch, located on the motor housing (D), to optimize the fan for seasonal performance. A ceiling fan will allow you to raise your thermostat setting in summer and lower your thermostat setting in winter without feeling a difference in your comfort. 4 D CAUTION: Turn fan off at wall switch and let blades (I) come to a complete stop before manually activating the reverse switch. I Reverse Switch 4a.
CARE AND MAINTENANCE At least twice each year, check mounting plate screws (E) and then tighten all screws on the fan. Clean motor housing (D) with only a soft brush or lint-free cloth to avoid scratching the finish. Clean blades (I) with a lint-free cloth. IMPORTANT: Shut off main power supply before beginning any maintenance. Do not use water or a damp cloth to clean the ceiling fan. • Total wattage for the light kit for this fan is 18 watts; do not attempt to replace the LEDs.
LIMITED LIFETIME WARRANTY The distributor warrants this fan to be free from defects in workmanship and materials present at time of shipment from the factory for Lifetime limited from the date of purchase. This warranty applies only to the original purchaser. The distributor agrees to correct any defect at no charge or, at our option, replace the ceiling fan with a comparable or superior model. To obtain warranty service, present a copy of your sales receipt as proof of purchase.